Bs en 1435-1997

Published on January 2017 | Categories: Documents | Downloads: 44 | Comments: 0 | Views: 579
of 36
Download PDF   Embed   Report

Comments

Content

BRITISH STANDARD

BS EN
1435:1997
Incorporating
Corrigendum No. 1
and Amendments
Nos. 1 and 2

Non-destructive testing
of welds —
Radiographic testing of
welded joints

The European Standard EN 1435:1997, with the incorporation of
amendments A1:2002 and A2:2003, has the status of a British Standard

ICS 25.160.40

12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:

BS EN 1435:1997

National foreword
This British Standard is the English language version of EN 1435:1997,
including amendments A1:2002 and A2:2003. It supersedes BS 2600-1:1983,
BS 2600-2:1973, BS 2910:1986 and BS 7257:1989, which are withdrawn.
The start and finish of text introduced or altered by amendment is indicated in
the text by tags !". Tags indicating changes to CEN text carry the number
of the CEN amendment. For example, text altered by CEN amendment A1 is
indicated by !".
As agreed by CEN/TC 121/SC 5 resolution 134/2000 and in accordance with
amendment A1:2002, the term “examination” has been replaced by “testing”
throughout the document.
The UK participation in its preparation was entrusted to Technical Committee
WEE/46, Non-destructive testing, which has the responsibility to:




aid enquirers to understand the text;
present to the responsible European committee any enquiries on the
interpretation, or proposals for change, and keep the UK interests
informed;
monitor related international and European developments and
promulgate them in the UK.

A list of organizations represented on this committee can be obtained on
request to its secretary.
Cross-references
The British Standards which implement international or European
publications referred to in this document may be found in the BSI Catalogue
under the section entitled “International Standards Correspondence Index”, or
by using the “Search” facility of the BSI Electronic Catalogue or of
British Standards Online.
This publication does not purport to include all the necessary provisions of a
contract. Users are responsible for its correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.

Summary of pages
This document comprises a front cover, an inside front cover, the EN title page,
pages 2 to 33 and a back cover.
The BSI copyright notice displayed in this document indicates when the
document was last issued.
This British Standard, having
been prepared under the
direction of the Engineering
Sector Board, was published
under the authority of the
Standards Board and comes
into effect on
15 December 1997
© BSI 15 March 2004

ISBN 0 580 28913 3

Amendments issued since publication
Amd. No.

Date

Comments

10616

August 1999

Correction to Table 2

Corrigendum No. 1

13985

15 November 2002 See national foreword

14938

15 March 2004

Changes to foreword and deletion of
Annex ZA

EUROPEAN STANDARD

EN 1435

NORME EUROPÉENNE

August 1997

EUROPÄISCHE NORM

May 2002

+ A1
+ A2

December 2003
ICS 25.160.40
Descriptors: Welded joints, fusion welding, butt welds, quality control, non-destructive tests, radiographic analysis, setting-up
conditions

English version

Non-destructive testing of welds —
Radiographic testing of welded joints
(includes amendments A1:2002 and A2:2003)

Contrôle non destructif des assemblages
soudés —
Contrôle par radiographie des assemblages
soudés
(inclut les amendements A1:2002 et A2:2003)

Zerstörungsfreie Prüfung von
Schweißverbindungen —
Durchstrahlungsprüfung von
Schmelzschweißungen
(enthält Änderungen A1:2002 und A2:2003)

This European Standard was approved by CEN on 1997-08-02. Amendment A1
was approved by CEN on 2002-05-05; amendment A2 was approved by CEN
on 2003-11-20. CEN members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any
CEN member. This European Standard exists in three official versions (English,
French, German). A version in any other language made by translation under
the responsibility of a CEN member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia,
Spain, Sweden, Switzerland and United Kingdom.

CEN
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung
Central Secretariat: rue de Stassart 36, B-1050 Brussels
© 1997 CEN — All rights of exploitation in any form and by any means reserved worldwide for CEN
national members.
Ref. No. EN 1435:1997 + A1:2002 + A2:2003 E

EN 1435:1997

Foreword

Foreword to amendment A2

This European Standard has been prepared by
Technical Committee CEN/TC 121, Welding, the
Secretariat of which is held by DS.

This document EN 1435:1997/A2:2003 has been
prepared by Technical Committee CEN/TC 121,
Welding, the Secretariat of which is held by DS.

This European Standard shall be given the status of
a national standard, either by publication of an
identical text or by endorsement, at the latest by
February 1998, and conflicting national standards
shall be withdrawn at the latest by February 1998.

This amendment to the European Standard
EN 1435:1997 shall be given the status of a national
standard, either by publication of an identical text
or by endorsement, at the latest by June 2004, and
conflicting national standards shall be withdrawn
at the latest by June 2004.

This document has been prepared under a mandate
given to CEN by the European Commission and the
European Free Trade Association.
According to the CEN/CENELEC Internal
Regulations, the national standards organizations
of the following countries are bound to implement
this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany,
Greece, Iceland, Ireland, Italy, Luxembourg,
Netherlands, Norway, Portugal, Spain, Sweden,
Switzerland and the United Kingdom.

Foreword to amendment A1

This document has been prepared under a mandate
given to CEN by the European Commission and the
European Free Trade Association.
According to the CEN/CENELEC Internal
Regulations, the national standards organizations
of the following countries are bound to implement
this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy,
Luxembourg, Malta, Netherlands, Norway,
Portugal, Slovakia, Spain, Sweden, Switzerland and
the United Kingdom.

This document EN 1435:1997/A1:2002 has been
prepared by Technical Committee CEN/TC 121,
Welding, the Secretariat of which is held by DS.
This amendment to the European Standard
EN 1435:1997 shall be given the status of a national
standard, either by publication of an identical text
or by endorsement, at the latest by November 2002,
and conflicting national standards shall be
withdrawn at the latest by November 2002.
This document has been prepared under a mandate
given to CEN by the European Commission and the
European Free Trade Association, and supports
essential requirements of EU Directive(s).
Annex A and Annex B are normative.
According to the CEN/CENELEC Internal
Regulations, the national standards organizations
of the following countries are bound to implement
this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany,
Greece, Iceland, Ireland, Italy, Luxembourg, Malta
Netherlands, Norway, Portugal, Spain, Sweden,
Switzerland and the United Kingdom.

2

© BSI 15 March 2004

EN 1435:1997

Contents

Page

Page
Foreword
2
1
Scope
5
2
Normative references
5
3
Definitions
5
3.1 nominal thickness, t
5
3.2 penetrated thickness, w
5
3.3 object-to-film distance, b
6
3.4 source size, d
6
3.5 source-to-film distance (SFD)
6
3.6 source-to-object distance, f
6
3.7 diameter, De
6
4
Classification of radiographic techniques 6
5
General
6
5.1 Protection against ionizing radiation
6
5.2 Surface preparation and stage of
manufacture
6
5.3 Location of the weld in the radiograph
6
5.4 Identification of radiographs
7
5.5 Marking
7
5.6 Overlap of films
7
5.7 Types and positions of image quality
indicators (IQI)
7
5.8 Evaluation of image quality
8
5.9 Minimum image quality values
8
5.10 Personnel qualification
8

6

Recommended techniques for making
radiographs
6.1 Test arrangements
6.2 Choice of tube voltage and radiation
source
6.3 Film systems and screens
6.4 Alignment of beam
6.5 Reduction of scattered radiation
6.6 Source-to-object distance
6.7 Maximum area for a single exposure
6.8 Density of radiograph
6.9 Processing
6.10 Film viewing conditions
7
Test report
Annex A (normative) Recommended number
of exposures which give an acceptable testing
of a circumferential butt weld
Annex B (normative) Minimum image quality
values

8
8
15
17
19
19
19
20
21
22
22
22
23
28

www.bzfxw.com

© BSI 15 March 2004

3

www.bzfxw.com

4

blank

EN 1435:1997

1 Scope
This European Standard specifies fundamental techniques of radiography with the object of enabling
satisfactory and repeatable results to be obtained economically. The techniques are based on generally
recognized practice and fundamental theory of the subject.
This standard applies to the radiographic testing of fusion welded joints in metallic materials.
It applies to the joints of plates or pipes. Besides its conventional meaning, “pipe” as used in this standard
should be understood to cover other cylindrical bodies such as tubes, penstocks, boiler drums and pressure
vessels. This standard complies with EN 444.
This standard does not specify acceptance levels of the indications.
If lower test criteria !are permitted by specification", the quality achieved may be significantly lower
than when this standard is strictly applied.

2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other publications.
These normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply
to this European Standard only when incorporated in it by amendment or revision. For undated references
the latest edition of the publication referred to applies.
EN 444, Non-destructive testing — General principles for the radiographic examination of metallic
materials using X- and gamma-rays.
EN 462-1, Non-destructive testing — Image quality of radiographs — Part 1: Concepts, image quality
indicators (wire type), determination of image quality value.

www.bzfxw.com

EN 462-2, Non-destructive testing — Image quality of radiographs — Part 2: Concepts, image quality
indicators (step/hole type), determination of image quality value.

EN 462-3, Non-destructive testing — Image quality of radiographs — Part 3: Image quality classes for
ferrous metals.

EN 462-4, Non-destructive testing — Image quality of radiographs — Part 4: Experimental evaluation of
image quality values and image quality tables.
EN 473, Qualification and certification of non-destructive personnel — General principles.
EN 584-1, Non-destructive testing — Industrial radiographic film — Part 1: Classification of film systems
for industrial radiography.
EN 584-2, Non-destructive testing — Industrial radiographic film — Part 2: Control of film processing by
means of reference value.
EN 25580, Non-destructive testing — Industrial radiographic illuminators — Minimum requirements.
(ISO 5580:1985)

3 Definitions
For the purpose of this standard, the following definitions apply.
3.1
nominal thickness, t
the nominal thickness of the parent material only. Manufacturing tolerances do not have to be taken into
account
3.2
penetrated thickness, w
the thickness of material in the direction of the radiation beam calculated on the basis of the nominal
thickness
for multiple wall techniques the penetrated thickness is calculated from the nominal thickness.

© BSI 15 March 2004

5

EN 1435:1997

3.3
object-to-film distance, b
the distance between the radiation side of the test object and the film surface measured along the central
axis of the radiation beam
3.4
source size, d
the size of the radiation source
3.5
source-to-film distance (SFD)
the distance between the radiation source and the film measured in the direction of the beam
3.6
source-to-object distance, f
the distance between the radiation source and the source side of the test object measured along the central
axis of the radiation beam
3.7
diameter, De
the nominal external diameter of the pipe

4 Classification of radiographic techniques
The radiographic techniques are divided into two classes:
— class A: basic techniques;
— class B: improved techniques.
Class B techniques will be used when class A might be insufficiently sensitive.

www.bzfxw.com

!Better techniques compared to class B are possible and may be defined by specification of all appropriate
test parameters."
The choice of radiographic technique shall be !defined by specification."
If, for technical reasons, it is not possible to meet one of the conditions specified for class B, such as type of
radiation source or the source-to-object distance, f, it may be !defined by specification" that the
condition selected may be that specified for class A. The loss of sensitivity shall be compensated by an
increase of minimum density to 3,0 or by the choice of a higher contrast film system. Because of the better
sensitivity compared to class A, the test specimen may be regarded as tested within class B. This does not
apply if the special SFD reductions as described in 6.6 for test arrangements 6.1.4 and 6.1.5 are used.

5 General
5.1 Protection against ionizing radiation
WARNING NOTICE. Exposure of any part of the human body to X-rays or gamma-rays can be highly
injurious to health. Wherever X-ray equipment or radioactive sources are in use, appropriate legal
requirements must be applied.
Local or national or international safety precautions when using ionizing radiation shall be strictly applied.
5.2 Surface preparation and stage of manufacture
In general, surface preparation is not necessary, but where surface imperfections or coatings might cause
difficulty in detecting defects, the surface shall be ground smooth or the coatings shall be removed.
Unless otherwise specified, radiography shall be carried out after the final stage of manufacture, e.g. after
grinding or heat treatment.
5.3 Location of the weld in the radiograph
Where the radiograph does not show the weld, high-density markers shall be placed on either side of the
weld.

6

© BSI 15 March 2004

EN 1435:1997

5.4 Identification of radiographs
Symbols shall be affixed to each section of the object being radiographed. The images of these symbols shall
appear in the radiograph outside the region of interest where possible and shall ensure unambiguous
identification of the section.
5.5 Marking
Permanent markings on the object to be tested shall be made in order to accurately locate the position of
each radiograph.
Where the nature of the material and/or its service conditions do not permit permanent marking, the
location may be recorded by means of accurate sketches.
5.6 Overlap of films
When radiographing an area with two or more separate films, the films shall overlap sufficiently to ensure
that the complete region of interest is radiographed. This shall be verified by a high-density marker on the
surface of the object which will appear on each film.
5.7 Types and positions of image quality indicators (IQI)
The quality of image shall be verified by use of IQI in accordance with EN 462-1 or EN 462-2.
The IQI used shall be placed preferably on the source side of the test object at the centre of the area of
interest on the parent metal beside the weld. The IQI shall be in close contact with the surface of the object.
Its location shall be made in a section of uniform thickness characterized by a uniform optical density on
the film.
According to the IQI type used, two cases shall be considered.

www.bzfxw.com

a) When using a wire IQI, the wires shall be directed perpendicular to the weld and its location shall
ensure that at least 10 mm of the wire length will show in a section of uniform optical density, which is
normally in the parent metal adjacent to the weld. At exposures in accordance with 6.1.6 and 6.1.7, the
IQI can be placed with the wires across to the pipe axis, and they should not be projected into the image
of the weld.
b) When using a step/hole IQI, it shall be placed in such a way that the hole number required is placed
close to the weld.

At exposures in accordance with 6.1.6 and 6.1.7, the IQI type used can be placed either on the source or on
the film side. If the IQIs cannot be placed in accordance with the above conditions, the IQIs will be placed
on the film side and the image quality shall be determined at least once from comparison exposure with
one IQI placed at the source side and one at the film side under the same conditions.
For double-wall exposures, when the IQI is placed on the film side, the above test is not necessary and in
this case reference should be made to the tables of correspondence given in Annex B.
Where the IQIs are placed at the film side, the letter “F” shall be placed near the IQI and it shall be noted
in the test report.
If steps have been taken to guarantee that radiographs or similar test objects and regions are produced
with identical exposure and processing techniques, and no differences in the image quality value are likely,
the image quality need not be verified for every radiograph, the extent of image quality verification being
subject to !specification".
For exposures of pipes with diameter 200 mm and above with the source centrally located, at least three
IQIs should be placed equally spaced at the circumference. The film(s) showing IQI images are then
considered representative for the whole circumference.

© BSI 15 March 2004

7

EN 1435:1997

5.8 Evaluation of image quality
The films shall be viewed in accordance with EN 25580.
From the testing of the image of the IQI on the radiograph, the number of the smallest wire or hole which
can be discerned is determined. The image of a wire is accepted if a continuous length of at least 10 mm is
clearly visible in a section of uniform optical density. In the case of the step/hole type IQI, if there are two
holes of the same diameter, both shall be discernible in order that the step be considered as visible.
The image quality obtained shall be indicated on the test report of the radiographic test. In each case, the
type of indicator used shall be clearly stated, as shown on the IQI.
5.9 Minimum image quality values
Table B.1 to Table B.12 in Annex B show the minimum quality values for ferrous materials. For other
materials these requirements or corresponding requirements may be !defined by specification". The
requirements shall be determined in accordance with EN 462-4.
5.10 Personnel qualification
Personnel performing non-destructive testing in accordance with this standard shall be qualified in
accordance with EN 473, or equivalent, to an appropriate level in the relevant industrial sector.

6 Recommended techniques for making radiographs
6.1 Test arrangements
6.1.1 General
Normally, radiographic techniques in accordance with 6.1.2, 6.1.3, 6.1.4, 6.1.5, 6.1.6, 6.1.7, 6.1.8 and 6.1.9
shall be used.

www.bzfxw.com

The elliptical technique (double wall/double image) in accordance with Figure 11 should not be used for
external diameter De > 100 mm, wall thickness t > 8 mm and weld width > De/4. Two 90° displaced images
are sufficient if t/De < 0,12. The distance between the two weld images shall be about one weld width.

When it is difficult to carry out an elliptic test at De k 100 mm, the perpendicular technique in accordance
with 6.1.7 may be used (see Figure 12). In this case, three exposures 120° or 60° apart are required.
For test arrangements in accordance with Figure 11, Figure 13 and Figure 14, the inclination of the beam
shall be kept as small as possible and be such as to prevent superimposition of the two images. The
source-to-object distance, f, shall be kept as small as possible, in accordance with 6.6. The IQI shall be
placed close to the film with a lead letter “F”.
Other radiographic techniques may be !specified," e.g. for reasons like geometry of the !test
object" or differences in material thickness. In 6.1.9 an example of such a case is presented. Multi-film
techniques shall not be used to reduce exposure times on uniform sections.
NOTE In Annex A the minimum number of radiographs necessary is given in order to obtain an acceptable radiographic coverage
of the total circumference of a butt weld in pipe.

8

© BSI 15 March 2004

EN 1435:1997

6.1.2 Radiation source located in front of the object and with the film at the opposite side
See Figure 1.

Key
S

radiation source

F

film

See Clause 3 for f, b, t.

Figure 1 — Test arrangement for plane walls and single-wall penetration
6.1.3 Radiation source located outside the object and with the film inside
See Figure 2, Figure 3 and Figure 4.

Figure 2 — Test arrangement for single-wall penetration of curved objects

Figure 3 — Test arrangement for single-wall penetration of curved objects (set-in weld)

© BSI 15 March 2004

9

EN 1435:1997

Figure 4 — Test arrangement for single-wall penetration of curved objects (set-on weld)
6.1.4 Radiation source centrally located inside the object and with the film outside
See Figure 5, Figure 6 and Figure 7.

Figure 5 — Test arrangement for single-wall penetration of curved objects
!

Figure 6 — Test arrangement for single-wall penetration of curved objects (set-in weld)
"

10

© BSI 15 March 2004

EN 1435:1997

Figure 7 — Test arrangement for single-wall penetration of curved objects (set-on weld)
6.1.5 Radiation source located off-centre inside the object and with the film outside
See Figure 8, Figure 9 and Figure 10.

Figure 8 — Test arrangement for single-wall penetration of curved objects

Figure 9 — Test arrangement for single-wall penetration of curved objects (set-in weld)

© BSI 15 March 2004

11

EN 1435:1997

Figure 10 — Test arrangement for single-wall penetration of curved objects (set-on weld)
6.1.6 Elliptic technique
See Figure 11.

Figure 11 — Test arrangement for double-wall penetration double image of curved objects for
evaluation of both walls (source and film outside the test object)
6.1.7 Perpendicular technique
See Figure 12.

Figure 12 — Test arrangement for double-wall penetration double image of curved objects for
evaluation of both walls (source and film outside the test object)

12

© BSI 15 March 2004

EN 1435:1997

6.1.8 Radiation source located outside the object and with the film on the other side
See Figure 13, Figure 14, Figure 15, Figure 16, Figure 17 and Figure 18.
!

Figure 13 — Test arrangement for double-wall penetration single image of curved objects for
evaluation of the wall next to the film, with the IQI placed close to the film
"

Figure 14 — Test arrangement for double-wall penetration single image

Figure 15 — Test arrangement for double-wall penetration single image of longitudinal welds

© BSI 15 March 2004

13

EN 1435:1997

Figure 16 — Test arrangement for double-wall penetration single image of curved objects for
evaluation of the wall next to the film

Figure 17 — Test arrangement for penetration of fillet welds

Figure 18 — Test arrangement for penetration of fillet welds

14

© BSI 15 March 2004

EN 1435:1997

6.1.9 Technique for different material thicknesses
See Figure 19.
Radiation source

Figure 19 — Multi-film technique
6.2 Choice of tube voltage and radiation source
6.2.1 X-ray devices up to 500 kV
To maintain a good flaw sensitivity, the X-ray tube voltage should be as low as possible. The maximum
values of tube voltage versus thickness are given in Figure 20.
For some applications where there is a thickness change across the area of object being radiographed, a
modification of technique with a slightly higher voltage may be used, but it should be noted that an
excessively high tube voltage will lead to a loss of defect detection sensitivity. For steel, the increment shall
be not more than 50 kV, for titanium not more than 40 kV, and for aluminium not more than 30 kV.

© BSI 15 March 2004

15

EN 1435:1997

1

Copper/nickel and alloys

2

Steel

3

Titanium and alloys

4

Aluminium and alloys

1)

X-ray voltage

2)

Penetrated thickness w

Figure 20 — Maximum X-ray voltage for X-ray devices up to 500 kV as a function of penetrated
thickness and material
6.2.2 Other radiation sources
The permitted penetrated thickness ranges for gamma ray sources and X-ray equipment above 1 MeV are
given in Table 1.
!If permitted by specification", the value for Ir 192 may further be reduced to 10 mm and for Se 75
to 5 mm.
On thin steel specimens, gamma rays from Se 5, Ir 192 and Co 60 will not produce radiographs having as
good a defect detection sensitivity as X-rays used with appropriate technique parameters. However,
because of the advantages of gamma ray sources in handling and accessibility, Table 1 gives a range of
thicknesses for which each of these gamma ray sources may be used when the use of X-rays is difficult.
For certain applications, wider wall thickness ranges may be permitted, if sufficient image quality can be
achieved.
In cases where radiographs are produced using gamma rays, the travel time to position the source shall not
exceed 10 % of the total exposure time.

16

© BSI 15 March 2004

EN 1435:1997

Table 1 — Penetrated thickness range for gamma ray sources and X-ray equipment with energy
from 1 MeV and above, for steel, copper and nickel-based alloys
Radiation source

Penetrated thickness, w
mm
Test class A

Tm 170
Yb 1691)
Se 752)
Ir 192
Co 60
X-ray equipment with energy from 1 MeV to 4 MeV
X-ray equipment with energy from 4 MeV to 12 MeV
X-ray equipment with energy above 12 MeV

wu5
1 u w u 15
10 u w u 40
20 u w u 100
40 u w u 200
30 u w u 200
w W 50
w W 80

Test class B

wu5
2 u w u 12
14 u w u 40
20 u w u 90
60 u w u 150
50 u w u 180
w W 80
w W 100

1) For

aluminium and titanium, the penetrated material thickness is 10 mm < w < 70 mm for class A and 25 mm < w < 55 mm for
class B.
2) For aluminium and titanium, the penetrated material thickness is 35 mm u w u 120 mm for class A.

6.3 Film systems and screens
For radiographic testing, film system classes shall be used in accordance with EN 584-1.
For different radiation sources the minimum film system classes are given in Table 2 and Table 3.
When using metal screens, good contact between films and screens is required. This may be achieved either
by using vacuum-packed films or by applying pressure.
For different radiation sources, Table 2 and Table 3 show the recommended screen materials and
thicknesses.
Other screen thicknesses may be !specified", provided that the required image quality is achieved.

© BSI 15 March 2004

17

EN 1435:1997

Table 2 — Film system classes and metal screens for the radiography of steel, copper and
nickel-based alloys
Radiation source

Penetrated
thickness, w
mm

X-ray potentials u 100 kV

Film system class1)
Class A

C5

X-ray potentials > 100 kV
to 150 kV
X-ray potentials > 150 kV
to 250 kV
Yb 169
w<5

Class B

C3

C4
C5

C3

Tm 170
wW5
X-ray potentials > 250 kV w u 50
to 500 kV
w > 50

C4
C5

C4
C5

Type and thickness of metal screens
Class A

Class B

None or up to 0,03 mm front and back
screens of lead
Up to 0,15 mm front and back screens of
lead
0,02 mm to 0,15 mm front and back
screens of lead
None or up to 0,03 mm front and back
screens of lead
0,02 mm to 0,15 mm front and back
screens of lead
0,02 mm to 0,2 mm front and back screens
of lead
0,1 mm to 0,2 mm front screens of lead2)
0,02 mm to 0,2 mm back screens of lead
0,1 mm to 0,2 mm front and back screens
of lead
0,02 mm to 0,2 mm 0,1 mm to 0,2 mm
front screens of
front screens of
lead2)
lead2)
0,02 mm to 0,2 mm back screens of lead
0,25 mm to 0,7 mm front and back screens
of steel or copper3)

Se 75

C5

C4

Ir 192

C5

C4

w u 100

C.5

C4

w > 100
w u 100

C5

C5
C3

C4

C5
C4

100 < w u 300 C 5

C4

w > 300
w u 100

C4

C5


Up to 1 mm front screen of tantalum5)

100 < w u 300 C 5
w > 300

C4
C5

No back screen
Up to 1 mm front screen of tantalum5)

Co 60

X-ray equipment with
energy from 1 MeV to 4
MeV
X-ray equipment with
energy from 4 MeV to 12
MeV

X-ray equipment with
energy above 12 MeV

w > 100
w u 100

0,25 mm to 0,7 mm front and back screens
of steel or copper3)

Up to 1 mm front screen of copper, steel or
tantalum4)
Back screen of copper or steel up to 1 mm
and tantalum up to 0,5 mm4)

Up to 0,5 mm back screen of tantalum
1) Better

film system classes may also be used.
2) Ready-packed films with a front screen up to 0,03 mm may be used if an additional lead screen of 0,1 mm is placed between the
object and the film.
3) In class A, 0,5 mm to 2,0 mm screens of lead may also be used.
4) In class A, lead screens 0,5 mm to 1 mm may be used !if permitted by specification."
5) Tungsten screens may be used by agreement.

18

© BSI 15 March 2004

EN 1435:1997

Table 3 — Film system classes and metal screens for aluminium and titanium
Radiation source

Film system class1)
Class A

X-ray potentials u
150 kV
X-ray potentials >
150 kV to 250 kV
X-ray potentials >
250 kV to 500 kV
Yb 169

C5

C3

Se 75
1) Better

Type and thickness of intensifying screens

Class B

None, or up to 0,03 mm front and up to
0,15 mm back screens of lead
0,02 mm to 0,15 mm front and back screens
of lead
0,1 mm to 0,2 mm front and back screens of
lead
0,02 mm to 0,15 mm front and back screens
of lead
!0,2 mm" front2) and 0,1 mm to 0,2 mm
back screens of lead

film system classes may also be used.
of 0,2 mm lead, a 0,1 mm screen with an additional filter of 0,1 mm may be used.

2) Instead

6.4 Alignment of beam
The beam of radiation shall be directed to the centre of the area being tested and should be perpendicular
to the object surface at that point, except when it can be demonstrated that certain imperfections are best
revealed by a different alignment of the beam. In this case, an appropriate alignment of the beam can be
permitted.
Other ways of radiographing may be !specified".
6.5 Reduction of scattered radiation
6.5.1 Filters and collimators
In order to reduce the effect of back scattered radiation, direct radiation shall be collimated as much as
possible to the section under test.
With Ir 192 and Co 60 radiation sources or in the case of edge scatter, a sheet of lead can be used as a filter
of low-energy scattered radiation between the object and the cassette. The thickness of this sheet is 0,5 mm
to 2 mm, in accordance with the penetrated thickness.
6.5.2 Interception of back scattered radiation
If necessary, the film shall be shielded from back scattered radiation by an adequate thickness of lead, at
least 1 mm, or of tin, at least 1,5 mm, placed behind the film–screen combination.
The presence of back scattered radiation shall be checked for each new test arrangement by a lead letter B
(with a minimum height of 10 mm and a minimum thickness of 1,5 mm) placed immediately behind each
cassette. If the image of this symbol records as a lighter image on the radiograph, it shall be rejected. If the
symbol is darker or invisible, the radiograph is acceptable and demonstrates good protection against
scattered radiation.
6.6 Source-to-object distance
The minimum source-to-object distance, fmin, depends on the source size d and on the object-to-film
distance, b.
The distance, f, shall, where practicable, be chosen so that the ratio of this distance to the source size, d,
i.e. f/d, is not below the values given by the following equations.
f
b 2⁄3
For class A: --- ≥ 7 ,5  ----------

d
mm

(1)

b 2⁄3
f
For class B: --- ≥ 15  ----------
 mm
d

(2)

b is given in millimetres (mm).

© BSI 15 March 2004

19

EN 1435:1997

If the distance b < 1,2t, the dimension b in equations (1) and (2) and Figure 21 shall be replaced by the
nominal thickness t.
For determination of the source-to-object distance, fmin, the nomogram in Figure 21 may be used.
The nomogram is based on equations (1) and (2).
In class A, if planar imperfections have to be detected, the minimum distance fmin shall be the same as for
class B in order to reduce the geometric unsharpness by a factor of 2.
In critical technical applications of crack-sensitive materials, more sensitive radiographic techniques than
class B shall be used.
When using the elliptic technique described in 6.1.6 or the perpendicular technique described in 6.1.7,
b shall be replaced by the external diameter, De, of the pipe in equations (1) and (2) and in Figure 21.
When the source is outside the object and the film is on the other side (the technique described in 6.1.8 as
double-wall penetration/single image), the source-to-object distance is determined only by the wall
thickness.
If the radiation source can be placed inside the object to be radiographed (the techniques shown in 6.1.4
and 6.1.5) to achieve a more suitable direction of test, and when a double-wall technique (see 6.1.6, 6.1.7
and 6.1.8) is avoided, this method should be preferred. The reduction in minimum source-to-object distance
should not be greater than 20 %.
When the source is located centrally inside the object and the film is outside (the technique shown in 6.1.4),
and provided that the IQI requirements are met, this percentage may be increased. However, the reduction
in minimum source-to-object distance shall not be greater than 50 %.
6.7 Maximum area for a single exposure
The number of radiographs for a complete testing of flat welds (see Figure 1 and Figure 15) and of curved
welds with the radiation source arranged off-centre (see Figure 2, Figure 3 and Figure 4 and Figure 8 to
Figure 16) should be specified in accordance with technical requirements.
The ratio of the penetrated thickness at the outer edge of an evaluated area of uniform thickness to that at
the centre beam shall not be more than 1,1 for class B and 1,2 for class A.
The densities resulting from any variation of penetrated thickness should not be lower than those indicated
in 6.8 and not higher than those allowed by the available illuminator, provided that suitable masking is
possible.
The size of the area to be tested includes the weld and the heat-affected zones. In general, about 10 mm of
parent metal shall be tested on each side of the weld.
A recommendation for the number of radiographs is indicated in Annex A, which gives an acceptable test
of a circumferential butt weld.

20

© BSI 15 March 2004

EN 1435:1997

1) Class B

2) Class A

Figure 21 — Nomogram for the determination of minimum source-to-object distance fmin in
relation to the object-to-film distance and the source size
6.8 Density of radiograph
Exposure conditions should be such that the minimum optical density of the radiograph in the area tested
is greater than or equal to the value given in Table 4.
Table 4 — Optical density of the radiographs
Class

A
B

Optical density1)

2,02)

W
W 2,33)

1) A

measuring tolerance of ±0,1 is permitted.
be reduced !if permitted by specification to 1,5."
3) May be reduced !if permitted by specification to 2,0."
2) May

High optical densities can be used with advantage where the viewing light is sufficiently bright in
accordance with 6.10.
In order to avoid unduly high fog densities arising from film ageing, development or temperature, the fog
density shall be checked periodically on a non-exposed sample taken from the films being used, and
handled and processed under the same conditions as the actual radiograph. The fog density shall not
exceed 0,3. Fog density here is defined as the total density (emulsion and base) of a processed, unexposed
film.

© BSI 15 March 2004

21

EN 1435:1997

When using a multi-film technique with interpretation of single films, the optical density of each film shall
be in accordance with Table 4.
If double film viewing is requested, the optical density of one single film shall not be lower than 1,3.
6.9 Processing
Films are processed in accordance with the conditions recommended by the film and chemical
manufacturer to obtain the selected film system class. Particular attention shall be paid to temperature,
developing time and washing time. The film processing shall be controlled regularly in accordance with
EN 584-2. The radiographs should be free from defects due to processing or other causes which would
interfere with interpretation.
6.10 Film viewing conditions
The radiographs should be tested in a darkened room on an area of the viewing screen with an adjustable
luminance in accordance with EN 25580. The viewing screen should be masked to the area of interest.

7 Test report
For each exposure, or set of exposures, a test report shall be made giving information on the radiographic
technique used, and on any other special circumstances which would allow a better understanding of the
results.
The test report shall include at least the following information:
a) name of the testing body;
b) object;
c) material;
d) heat treatment;
e) geometry of the weld;
f) material thickness;
g) welding process;
h) specification of test, including requirements for acceptance;
i) radiographic technique and class, required IQI sensitivity in accordance with this standard;
j) test arrangement in accordance with 6.1;
k) system of marking used;
l) film position plan;
m) radiation source, type and size of focal spot, and identification of equipment used;
n) film, screens and filters;
o) used tube voltage and current or source activity;
p) time of exposure and source-to-film distance;
q) processing technique: manual/automatic;
r) type and position of image quality indicators;
s) results of test, including data on film density, reading of IQI;
t) any deviation from this standard, by special agreement;
u) name, !reference to certificate and signature of the responsible person(s);"
v) date(s) of exposure and test report.

22

© BSI 15 March 2004

EN 1435:1997

Annex A (normative)
Recommended number of exposures which give an acceptable test of a
circumferential butt weld
The minimum number of exposures required is presented in Figure A.1, Figure A.2, Figure A.3 and
Figure A.4, which are valid for pipes with an outside diameter exceeding 100 mm.
When the deviation of the wall thickness of the joint to be tested when using a single exposure, %t/t, does
not exceed 20 %, Figure A.3 and Figure A.4 are used. This technique is recommended only when the
possibility of having transverse cracks is small or when the weld is tested for such imperfections by other
non-destructive test methods.
When Dt/t is less than or equal to 10 %, Figure A.1 and Figure A.2 are used. In this case it is likely that
transverse cracks will also be detected.
If the object is examined for single transverse cracks, then the required minimum number of radiographs
will increase compared with the values in Figure A.1, Figure A.2, Figure A.3 and Figure A.4.

© BSI 15 March 2004

23

EN 1435:1997

!

Nominal thickness t/ outside pipe diameter D

Figure A.1 — Minimum number of exposures, N, for single-wall penetration with source
outside, with a maximum permissible increase in penetrated thickness ∆t/t due to inclined
penetration in the areas to be evaluated of 10 %, as a function of ratios t/De and De /f
"

24

© BSI 15 March 2004

EN 1435:1997

!

1

Pipe wall

Nominal thickness t/ outside pipe diameter D

Figure A.2 — Minimum number of exposures, N, for off-centre penetration with source inside
and double-wall penetration, with a maximum permissible increase in penetrated thickness
%t/t due to inclined penetration in the areas to be evaluated of 10 %, as a function of ratios t/De
and De/SFD
"

© BSI 15 March 2004

25

EN 1435:1997

!

Nominal thickness t/ outside pipe diameter D

Figure A.3 — Minimum number of exposures, N, for single-wall penetration with source
outside, with a maximum permissible increase in penetrated thickness ∆t/t due to inclined
penetration in the areas to be evaluated of 20 %, as a function of ratios t/De and De/f
"

26

© BSI 15 March 2004

EN 1435:1997

!

1
Pipe wall
Nominal thickness t/ outside pipe diameter D

Figure A.4 — Minimum number of exposures, N, for off-centre penetration with source inside
and double-wall penetration, with a maximum permissible increase in penetrated thickness
%t/t due to inclined penetration in the areas to be evaluated of 20 %, as a function of ratios t/De
and De/SFD
"
© BSI 15 March 2004

27

EN 1435:1997

Annex B (normative)
Minimum image quality values
Single-wall technique; IQI on source side
Table B.1 — Wire IQI
Image quality class A
Nominal thickness t

IQI value1)

mm

up to 1,2
above 1,2 to 2,0
above 2,0 to 3,5
above 3,5 to 5,0
above 5,0 to 7
above 7 to 10
above 10 to 15
above 15 to 25
above 25 to 32
above 32 to 40
above 40 to 55
above 55 to 85
above 85 to 150
above 150 to 250
above 250

W 18
W 17
W 16
W 15
W 14
W 13
W 12
W 11
W 10
W9
W8
W7
W6
W5
W4

1) When

using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
10 mm to 24 mm: up to two values;
above 24 mm to 30 mm; up to one value.

28

© BSI 15 March 2004

EN 1435:1997

Table B.2 — Step/hole IQI
Image quality class A
Nominal thickness t

IQI value1)

mm

up to 2,0
above 2,0 to 3,5
above 3,5 to 6
above 6 to 10
above 10 to 15
above 15 to 24
above 24 to 30
above 30 to 40
above 40 to 60
above 60 to 100
above 100 to 150
above 150 to 200
above 200 to 250
above 250 to 320
above 320 to 400
above 400

H3
H4
H5
H6
H7
H8
H9
H 10
H 11
H 12
H 13
H 14
H 15
H 16
H 17
H 18

1) When

using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
10 mm to 24 mm: up to two values;
above 24 mm to 30 mm: up to one value.

Single-wall technique; IQI on source side
Table B.3 — Wire IQI
Image quality class B
Nominal thickness t

IQI value1)

mm

up to 1,5
above 1,5 to 2,5
above 2,5 to 4
above 4 to 6
above 6 to 8
above 8 to 12
above 12 to 20
above 20 to 30
above 30 to 35
above 35 to 45
above 45 to 65
above 65 to 120
above 120 to 200
above 200 to 350
above 350

W 19
W 18
W 17
W 16
W 15
W 14
W 13
W 12
W 11
W 10
W9
W8
W7
W6
W5

1) When

using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
12 mm to 40 mm: up to one value.

© BSI 15 March 2004

29

EN 1435:1997

Table B.4 — Step/hole IQI
Image quality class B
Nominal thickness t

IQI value1)

mm

up to 2,5
above 2,5 to 4
above 4 to 8
above 8 to 12
above 12 to 20
above 20 to 30
above 30 to 40
above 40 to 60
above 60 to 80
above 80 to 100
above 100 to 150
above 150 to 200
above 200 to 250

H2
H3
H4
H5
H6
H7
H8
H9
H 10
H 11
H 12
H 13
H 14

1) When

using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
12 mm to 40 mm: up to one value.

Double-wall technique; double image; IQI on source side
Table B.5 — Wire IQI
Image quality class A
Penetrated thickness w

IQI value

mm

up to 1,2
above 1,2 to 2
above 2 to 3,5
above 3,5 to 5
above 5 to 7
above 7 to 12
above 12 to 18
above 18 to 30
above 30 to 40
above 40 to 50
above 50 to 60
above 60 to 85
above 85 to 120
above 120 to 220
above 220 to 380
above 380

30

W 18
W 17
W 16
W 15
W 14
W 13
W 12
W 11
W 10
W9
W8
W7
W6
W5
W4
W3

© BSI 15 March 2004

EN 1435:1997

!Double-wall technique; double image; IQI on source side"
Table B.6 — Step/hole IQI
Image quality class A
Penetrated thickness w

IQI value1)

mm

up to 1
above 1 to 2
above 2 to 3,5
above 3,5 to 5,5
above 5,5 to 10
above 10 to 19
above 19 to 35
1)

H3
H4
H5
H6
H7
H8
H9

When using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
up to 3,5 mm: up to two values;
above 3,5 mm to 10 mm: up to one value.

Double-wall technique; double image; IQI on source side
Table B.7 — Wire IQI
Image quality class B
Penetrated thickness w
mm

up to 1,5
above 1,5 to 2,5
above 2,5 to 4
above 4 to 6
above 6 to 8
above 8 to 15
above 15 to 25
above 25 to 38
above 38 to 45
above 45 to 55
above 55 to 70
above 70 to 100
above 100 to 170
above 170 to 250
above 250

IQI value

W 19
W 18
W 17
W 16
W 15
W 14
W 13
W 12
W 11
W 10
W9
W8
W7
W6
W5
Table B.8 — Step/hole IQI
Image quality class B

Penetrated thickness w

IQI value1)

mm

up to 1
above 1 to 2,5
above 2,5 to 4
above 4 to 6
above 6 to 11
above 11 to 20
above 20 to 35
1)

H2
H3
H4
H5
H6
H7
H8

When using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
4 mm to 11 mm: up to one value.

© BSI 15 March 2004

31

EN 1435:1997

Double-wall technique; single or double image; IQI on film side
Table B.9 — Wire IQI
Image quality class A
Penetrated thickness w

IQI value

mm

up to 1,2
above 1,2 to 2
above 2 to 3,5
above 3,5 to 5
above 5 to 10
above 10 to 15
above 15 to 22
above 22 to 38
above 38 to 48
above 48 to 60
above 60 to 85
above 85 to 125
above 125 to 225
above 225 to 375
above 375

W 18
W 17
W 16
W 15
W 14
W 13
W 12
W 11
W 10
W9
W8
W7
W6
W5
W4
Table B.10 — Step/hole IQI
Image quality class A

Penetrated thickness w

IQI value1)

mm

up to 2
above 2 to 5
above 5 to 9
above 9 to 14
above 14 to 22
above 22 to 36
above 36 to 50
above 50 to 80
1)

H3
H4
H5
H6
H7
H8
H9
H 10

When using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
5 mm to 9 mm: up to two values;
above 9 mm to 22 mm: up to one value.

32

© BSI 15 March 2004

EN 1435:1997

Double-wall thickness; single or double image; IQI on film side
Table B.11 — Wire IQI
Image quality class B
Penetrated thickness w

IQI value

mm

up to 1,5
above 1,5 to 2,5
above 2,5 to 4
above 4 to 6
above 6 to 12
above 12 to 18
above 18 to 30
above 30 to 45
above 45 to 55
above 55 to 70
above 70 to 100
above 100 to 180
above 180 to 300
above 300

W 19
W 18
W 17
W 16
W 15
W 14
W 13
W 12
W 11
W 10
W9
W8
W7
W6
Table B.12 — Step/hole IQI
Image quality class B

Penetrated thickness w

IQI value1)

mm

up to 2,5
above 2,5 to 5,5
above 5,5 to 9,5
above 9,5 to 15
above 15 to 24
above 24 to 40
above 40 to 60
above 60 to 80
1)

H2
H3
H4
H5
H6
H7
H8
H9

When using Ir 192 sources, IQI values worse than the listed values can be accepted as follows:
5,5 mm to 9,5 mm: up to two values;
above 9,5 mm to 24 mm: up to one value.

© BSI 15 March 2004

33

BS EN 1435:1997

BSI — British Standards Institution
BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of
British Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001.
Fax: +44 (0)20 8996 7001. Email: [email protected]. Standards are also
available from the BSI website at http://www.bsi-global.com.
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: [email protected].
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001.
Email: [email protected].
Information regarding online access to British Standards via British Standards
Online can be found at http://www.bsi-global.com/bsonline.
Further information about BSI is available on the BSI website at
http://www.bsi-global.com.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
permission from BSI.

BSI
389 Chiswick High Road
London
W4 4AL

This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.
Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.
Email: [email protected].

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close