Hd Powerlift Plus Excelerator Install

Published on May 2016 | Categories: Types, Instruction manuals | Downloads: 37 | Comments: 0 | Views: 181
of 30
Download PDF   Embed   Report

Genie Garage Door HD Powerlift Plus Excelerator Installation Manual

Comments

Content


For 7’ 6” Doors. Extension Kit is available for 8’ Doors
Included Wall Console MUST be installed prior to Operation
of this Garage Door Opener.
Safe-T-Beam
®
Safety Reverse System MUST be Installed and
the Force Controls MUST be Properly set to close door.
This Equipment meets or exceeds all Federal, State and UL 325
Safety Requirements.
Will not operate “twice as fast” on one-piece doors.
3531836147
S
A
V
E

T
H
I
S

M
A
N
U
A
L

F
O
R

F
U
T
U
R
E

R
E
F
E
R
E
N
C
E
Complete with iNtelliCoDe®
Remote CoNtRol aND SeRieS ii
eleCtRoNiCS
Having Difficulty? Need Help?
Please call us: 1-800-35-GENIE (354-3643)
www.geniecompany.com
Please have Model information ready when calling.
Safety Information 2
Important Installation Instructions 2
Safety Features 2
Pre-installation Checklist 3
Garage Door Opener Assembly 9
Record Data (for Service) 11
Garage Door Opener Installation 12
Accessories 22
Maintenance 23
Troubleshooting Guide 24
Wiring Diagram 27
Warranty information 28
table of CoNteNtS
2
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Garage Doors are heavy objects that move with the help of springs
under high tension and electric opening equipment Since moving
objects, springs under tension, and electric opening equipment
may cause injuries, your safety and the safety of others depend on
you reading and understanding the information in this manual
POTENTIAL HAZARD EFFECT PREVENTION
• Keep people clear of opening while door is moving.
• Do Not allow children to play with the door opener
• Do Not operate a door that jams or one that has a broken spring
MOVING DOOR
WARNING:
Can Cause Serious
Injury or Death
• Disconnect cord or turn off power before removing opener cover.
• When replacing cover, make sure wires are not pinched or near
moving parts
• Make sure opener is properly grounded.
ELECTRICAL SHOCK
• Do Not try to remove, repair or adjust springs or anything to
which door spring parts are fastened, such as, wood blocks,
steel brackets, cables or other like items
• Repairs and adjustments must be made by a trained service
person using proper tools and instructions
HIGH SPRING TENSION
Safe-T-Beam
®
(STB) Non-Contact Reversing System
Places an invisible beam across door opening The door
will reverse during down travel to the fully open position if
anything passes through beam
Safe-T-Reverse
®
Contact Reversing System
Automatically stops and reverses a closing door within two
seconds of contact with an object
Safe-T-Stop
®
Timed Reversed System
Automatically opens a closing door if door does not close
within 30 seconds
Force Guard
®
Control
Used to set the force required for opening and
closing the door For maximum safety, set the minimum
force required to fully open and close door
Automatic Lighting System
Two light bulbs up to 60 Watts max each, are used
for safer entries and exits The light turns on when door is
activated and automatically turns off 45 minutes later
Manual Emergency Release
Allows the garage door to be opened or closed manually
for emergencies or maintenance

impoRtaNt iNStallatioN
iNStRUCtioNS
1 READ AND FOLLOW ALL SAFETY, INSTALL ATION AND
OPERATION INSTRUCTIONS If you have any
questions or do not understand an instruction, call
customer service at 1-800-35-GENIE
2 Do Not install opener on an improperly balanced
door An improperly balanced door may cause
severe injury Repairs and adjustments to cables,
spring assemblies, and other hardware must be
made by a trained service person using proper tools
and instructions
3 Remove all handles and ropes, and disable all locks
connected to the door before installing the opener
4 Install door opener at least 7’ above the floor
Mount the Emergency Release Knob 6’ above
the floor
5 Do Not connect the opener to the power source
until instructed to do so
6 Locate the Wall Console:
• Within sight of the garage door.
• At a minimum height of 5’, so small children
cannot reach it
• Away from all moving parts of the garage door.
7 Install the entrapment WARNING label next to the
Wall Console Install the Emergency Release
Tag on the Emergency Release Lever
8 The operator must reverse when the door contacts a
1-1/2 inch high object on the floor at the center of
the doorway This is the size of a 2” x 4” board
laid flat
to ReDUCe the RiSk of SeveRe iNjURy oR Death:

WARNING:
Safety iNfoRmatioN
Safety featUReS
If you have garage door related questions or do not understand the
information presented, call your nearest Genie Factory Authorized
Dealer listed at www.geniecompany.com, or customer Service at
1-800-35-GENIE.
WARNING:
Can Cause Serious
Injury or Death
WARNING:
Can Cause Serious
Injury or Death
3
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
pRe-iNStallatioN CheCkliSt
This Opener includes parts and supplies needed to install in most garages and
connect to most garage doors There are many variations of garages and garage
doors A few additional parts and supplies may be needed to install Opener into
your garage and connect to your garage door While checking items listed
below, note any additional items you will need
Tools used in this section:
• 12’+ Tape Measure • Pencil • Ladder • Level
Check following items before assembling Opener:

CheCk DooR CoNDitioN aND
thiCkNeSS
Check condition of vertical stile in center of door, and its connection to door’s
top and bottom beams
A If door frame is nailed together and not a solid connection, door frame
must be braced or reinforced before installing Opener
B If door is “lightweight” (made with frame and skin - not solid), door
(including door frame) must be braced or reinforced before
installing Opener
C A door opener reinforcement bracket may also be needed to connect
garage door to Opener’s Door Bracket This Opener is designed for
installation on a properly braced sectional door or solidly braced
one-piece door
D Contact your Genie Factory Authorized Dealer or dealer of your garage
door for any necessary bracing and a door opener reinforcement
bracket (if needed) before proceeding
E If you have a wooden door, measure door’s thickness (1/4” x 2”) Lag
Screws are included for installing Door Bracket onto door If your door
is less than 2” thick, brace door or use shorter Door Bracket Lag
Screws (1/4” x 1-1/4” – not included)
Check Step 1:

CheCk GaRaGe DooR
aliGNmeNt, opeRatioN,
aND balaNCe
A Raise door, check alignment and see if it moves freely (Figure 1) If door
appears out of alignment, binds, or does not move smoothly, contact a
Genie Factory Authorized Dealer or dealer of your garage door for repairs
and adjustments to door mechanism
B Raise door to 3’ – 4’ above ground and carefully let go Door should stay
stationary Slight movement is acceptable More than slight movement
means door is out of balance Contact a Genie Factory Authorized Dealer
or dealer of your garage door
for repairs and adjustments
to door mechanism
C Check door type Make
a note of whether it is a
sectional or a one-piece
door (Figure 2)
Check Step 2:

WARNING:
If your door sticks, binds, or is out of
balance, have it adjusted by a Genie Factory
Authorized Dealer Door springs, cables,
pulleys, brackets and associated hardware
are under extreme tension and can cause
serious injury or death

NOTE
The Excelerator Opener is equipped with an
Automatic Garage Door Balance Detection
System See Troubleshooting Guide on
page 27
KEEP FEET CLEAR OF DOOR
3’ - 4’
Sectional Door
3’ - 4’
One-Piece Door
Figure 1 Checking door balance
Figure 2 Note Door Type
Torsion Springs
Extension Springs
Center
Stile
Center Stile
Header Area
4
For Help, call 1-800-35-GENIE or visit www.geniecompany.com

meaSURe GaRaGe DooR heiGht
Measure garage door height (7’-6”, 8’-0”, or taller) with
tape measure
A If door height is 7’-6” or less, continue with Check Step 4
B If door height is 8’-0”, you need an Excelerator Rail Extension
Kit. (Figure 3) (See Accessories Order Form, page 31/32)
C If door height is taller than 8’-0”, the Excelerator you pur
chased is the wrong version Contact your Genie Customer
Service Representative at 1-800-35-GENIE
Check Step 3:

CheCk DooR heaDeR aRea

A Find vertical center line of door and header:
• Close door
• Measure door width at top
• Mark a point at center of door and on header directly
above door Draw a center line to connect points
B Find Header Bracket mounting height (Figure 4):
(Do not attach Header Bracket)
• Raise door, watching top edge of door and stop door
when its edge reaches its highest point
• Measure distance (“H”) from top edge of door to floor
– For sectional doors, add 2-1/2” to “H” Mark a point
on center line Bottom of Header Bracket will be
installed here
– For one-piece doors, add 6” to “H” Mark this point
on center line Bottom of Header Bracket will be
installed here
C Check wall for a stud or a solid header at your mark:
(If checking a finished wall, a stud finder may be helpful)
• If location is above Header, a 2” x 6” board must be
screwed to studs beside your mark with at least two Lag
Screws and Flat Washers (not provided)
• Transfer your mark to new mounting board
Check Step 4:

NOTE
The header is a heavily reinforced section of the wall just
above the top of the garage door opening

NOTE
• For both types of doors:
– If the ceiling in your garage is so low that there is
not at least a 3” space above the Header Bracket
mounting point, contact a Genie Factory
Authorized Dealer
• If a door spring is in the way, place the Header
Bracket avove the spring Do Not move the door spring
Rail Extension for
8’ door
Figure 3 Rail Extension Kit
Figure 4 Find Highest Point of door travel
SECTIONAL DOOR
ONE-PIECE DOOR
5
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


CheCk poweR heaD
moUNtiNG aRea
Check ceiling or space above where Opener Power Head will be
mounted (Figure 5):
A Measure from garage door center line mark toward rear
of garage:
• Approximately 10’ back if garage has a 7’ 6” door
• Approximately 11’ back if garage has an 8’ 0” door
• Approximately 13’ back if garage has an 10’ 0” door
• Approximately 14’ back if garage has an 12’ 0” door

B Find location of ceiling joist or truss above where Opener
Power Head will be and estimate type and quantity of
materials needed for your installation (Figure 6)
Check Step 5:

NOTE
Mounting Straps are included to attach the Opener to
most garage ceilings Garage construction varies widely
Additional mounting straps or angle iron may be needed for
your installation


CheCk CeiliNG foR GRoUNDeD
poweR SoURCe
A Check that there is a 15 Amp 120 Volt grounded electrical
outlet or grounded permanent wiring box (per building
code) within 3’ of Opener Power Head:
• If not, an outlet or wiring box must be installed Contact
a licensed electrician for installation
• If building codes require permanent wiring, Power Head
must be partially disassembled to install appropriate
wiring in place of Power Cord See page 19
Check Step 6:

NOTE
Permanent wiring must be installed by a Licensed
Electrician Not all Genie Factory Authorized Dealers are
Licensed Electricians Contact someone who is a Licensed
Electrician
120 Volt grounded outlet
or wiring box within 3 feet of
Power Head
10’
for 7-1/2’ doors
11’
for 8’ doors
Door Center Line
Figure 5 Check Power Head location
Mounting Straps Support board added
for longer spans
Perforated
Angle Iron
(Angle iron not included)
Figure 6 Mounting methods for open beam and finished ceilings
FINISHED CEILINGS
Locate ceiling joists or
trusses using
a stud finder
or similar
device
Attach angle iron
(not included) to
joists or trusses
through finish material
using Lag Screws
6
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


CheCk Safe-t-beam®
moUNtiNG bRaCket loCatioN
Check for wood garage frame, jamb, or masonry at mounting loca-
tion (6” above floor) with attachment tabs facing away from garage
door (Figure 7)
A If you cannot mount Safe-T-Beam® Mounting Bracket to
wood frame:
• Concrete screws and concrete anchors (not included)
must be used to mount Brackets on masonry with
attachment tabs facing away from garage door
• Safe-T-Beam® Mounting Bracket Extensions may be used
(not included - available from a Genie Factory Authorized
Dealer or through Accessories Order Form on pages 31/32)
Check Step 7:


ReCommeNDeD toolS
A Tools (Figure 8):
B Additional tools to make installation easier:
• Slotted and phillips screw-driver bits
• Stud finder
• Sheet-metal cutting snips
Check Step 8:
D

Remove exiStiNG GaRaGe
DooR loCkS
Check that the garage door locks, rope, and T-Handles are removed
from the garage door before starting the installation
A If your garage does not have a separate entry door, it is highly
recommended to install a Genie Emergency Release Kit (GER-2)
Emergency Release Kit lets you open garage door from outside if
there is a power failure (Please see Accessories Order Form on
pages 31/32)
Check Step 9:
Before going further, get any items and tools
needed for your installation
p Safe-T-Beam® Sensor Mounting Bracket Extensions (dealer)
p Garage door opener reinforcement bracket (dealer)
p Garage door frame reinforcement brackets, screws, bracing
or reinforcement kits (dealer)
p Lag Screws (1-1/4”or 1-1/2” ) for a wood door less than 2”
thick (store)
p Electrical outlet and/or wiring (supplied by a
licensed electrician)
p Excelerator Extension Kit (for 8’ garage doors) (store)
p Sufficient angle iron or strapping for hanging Power Head
(store)
p Two 60 Watt light bulbs
(130 Volt bulbs recommended)(store)
p GER-2 Emergency Release Kit for entry during power failure
(store)
p Wood for header, ceiling, and/or door bracing reinforcement
(if needed)
p Masonry fasteners for Safe-T-Beam® Bracket installation,
(if needed)
p Masonry drill bit (if needed)
Source
Sensor
Safe-T-Beam®
Mounting Bracket
Top of
Bracket
6” above
floor
Figure 7 Mounting Safe-T-Beam® Components
Figure 8 Recommended Tools
7
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Item Part Name Quantity
Item Part Name Required
1-Pc Rail 3-Pc Rail
1 Power Head Assembly (main carton) 1 1
2 1/4”-20 x 13/16” Hex Head Shoulder Bolt (blue bag) 2 2

(yellow shoulder bolt)
3 Rail Assembly, 1 piece (separate carton) 1
4 Rail Assembly, 3 piece (main carton) 1
4A First Rail Section (main carton) 1
4B Middle Rail Section (main carton) 1
4C End Rail Section (main carton) 1
8 1/4”-20 Hex Serrated Flange Nut (blue bag) 4 4
9 Rail Clamps (main carton) 4
10 5/16”-18 x 11/16” Hex Head Shoulder Bolt (blue bag) 8
11 5/16”-18 Hex Serrated Flange Nut (blue & orange bags) 12
12 Magnetic Carriage Assembly (main carton) 1 1
13 Collar (blue bag) 3
14 Retaining Clip (blue bag) 3
15 Rail Strap (blue bag) 1 1
16 1/4”-20 Hex Head Bolt (blue bag) 2 2
18 Open Limit Switch Assembly (White)(green bag) 1 1
19 Close Limit Switch Assembly (Brown) (green bag) 1 1
21 # 8-32 x 1” Hex Head Screw (green bag) 2 2
22 Emergency Release Cord (carriage) 1 1
23 Emergency Release Cord (main carton)
24 Emergency Release Knob (green bag) 1 1
25 Emergency Release Tag (carriage) 1 1
26 Header Bracket (orange bag) 1 1
28 Door Bracket (orange bag) 1 1
30 1/4” x 2” Lag Screw (orange bag) 8
31 Straight Door Arm (main carton) 1 1
32 Clevis Pin, 3/8” x 15/16” (yellow bag) 2 2
33 Cotter Pin, 073” dia (yellow bag) 2 2
34 Curved Door Arm (main carton) 1 1
35 3/8” x 7/8” Hex Head Bolt (yellow bag) 2 2
36 3/8” Hex Serrated Flange Nut (yellow bag) 2 2
37* 2-Conductor Wire (main carton) 1 Roll 1 Roll
38* Insulated Staple (red bag) approx 30 approx 30
40* Wall Console (main carton) 1 1
41* # 6 x 1-1/4” Pan Head Screw (red bag) 2 2
42* Entrapment Warning Label (manual)(main carton) 1 1
43* Safe-T-Beam Sensor (Green LED)(main carton) 1 1
44* Safe-T-Beam Source (Red LED)(main carton) 1 1
45* Safe-T-Beam Bracket (yellow bag) 2 2
46 Coupler (blue bag) 1 1
47* # 10 x 1 1/4” Phillips Hex Head Screw (yellow bag) 4 4
48* One Button Remote Control (main carton)
49* Three Button Remote Control (main carton)
50* Wireless Keypad (main carton)
51* Two Button Remote Control (main carton)
52* Safety & Maintenance Guide (manual)(main carton) 1 1
53 Wire Clip (green bag) 7
54 Carriage Stop 1 1
55* 5/16”-18 x 3/4” Hex Head Bolt (orange bag) 3
56 1/4-20 x 3/4” Self-drilling Screw (orange bag) 3 3
57 Mounting Straps (main carton) 2 2
58 Wall Button (red bag) 1 1
* Denotes items not shown on page 8 These items will be illustrated
throughout the manual as required
Parts List
[
1
]
Item Part Name
1A Lens
1B Top Plate Assembly
1C Light Socket (2)
1D Motor Assembly
1E Cover
1G Motor Drive Board
1H Controller Board
1K # 10-24 x 3/8” Hex Head
1L # 8-32 x 1” Phillips Screw
1M # 8-32 x 3/8” Slotted Hex Head Screw
1P Power Cord
poweR heaD aSSembly exploDeD view
POWER HEAD ASSEMBLY PARTS LIST
10’ &12’ only
varies
/

model
varies
/

model
varies
/

model
varies
/

model
varies
/

model
varies
/

model
varies
/

model
varies
/

model
varies
/

model
Serial Number
Model Number
varies
/

model
varies
/

model
8
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
exCeleRatoR haRDwaRe exploDeD view
NOTE
One-Piece Rail Assembly (Genie Pro only) for 10’ or 12’ door includes:
• Special “Close” Limit Switch with longer Wires
• 96” Emergency Release Cord (yellow)
• Rail Support Kit.
Opener will not function unless Safe-T-Beam® System is installed and Force Controls are properly set
Rail Assembly (1 piece)
(Packaged separately)
3
9
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
GaRaGe DooR opeNeR aSSembly


Ch CoNNeCt Rail to poweR
heaD
opeN blUe paRtS baG
A Turn Power Head upside down and place on a flat
level surface
B Install Coupler on Motor Shaft (Figure 9)
C Connect first Rail Section to Opener Power Head Connect
with 2 (1/4”-20) (yellow) Hex Head Shoulder Bolts and
2 (1/4” -20) Hex Serrated Flange Nuts (Figure 10)
Finger-tighten until later
D If you have a 1-piece rail unit, skip Assembly Step 2
Assembly Step 1:

CAUTION
The Drive Screw and Rail Liner can slide out of Rail Sections
Keep Rail Sections level until the Opener is fully assembled.


Ch iNStall RemaiNiNG Rail
SeCtioNS
Assembly Step 2:
NOTE
If the Extension Assembly (GSXL8) is needed, attach
it per instructions supplied with kit
Rail Strap
5/16”-18 Hex Serrated Flange Nuts
5/16”-18 Hex Head Shoulder Bolts
1/4”-20 Hex
Serrated Flange Nuts
1/4”-20 Hex Head
Shoulder Bolts
(yellow)
Coupler
1/4”-20 Hex
Head Bolts
Carriage
Stop Collars + spare Retaining Clips + spare
Hardware (blue bag)
First Rail
Section
Coupler
Power Head
Assembly
Figure 9 Install Bumper, Coupler and 1st Rail Section
Figure 10 Bolt 1st Rail Section to Power Head
A Arrange arrows on Rail Sections to point in same direction
and away from Power Head:
• Push Middle Drive Screw out about 2” toward Power Head
• Slide Collar over Middle Drive Screw Hook (Figure 11A)
• Turn Middle Screw by hand to align Drive Screw Hooks
between First and Middle Rail Sections
• Latch two Hooks together and slide Collar over them
(Figure 11B) and (Figure 11C)
• Snap Clip on Drive Screw next to Collar (Figure11D)
B Attach Middle Rail Section to First Rail Section, using 2 Rail
Clamps, 4 (5/16”-18) Hex Shoulder Bolts, and 4 (5/16”-18) Hex
Head Serrated Flange Nuts onto Bolts (Figure 11)
Finger-tighten until later (Middle Rail Section looks the
same on both ends See page 8)
C Attach End Rail Section to Middle Rail Section following
procedures in step A & B
Figure 11 Attach Middle Rail Section
Retaining Clips
Middle Rail
Section
Rail Clamps Collar
Arrows point toward door
11A. Slip on collar
11B. Engage Hooks
11C. Slide Collar over Hooks
11D. Snap on Retaining Clip
10
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch iNStall maGNetiC CaRRiaGe
aSSembly oNto RailS
Assembly Step 3:
A Slide the Carriage Stop into slot on End Rail (Figure 12)
B Place Magnetic Carriage Assembly Lever in “release” position
C Slide Magnetic Carriage Assembly into slot on End Rail
Section with arrow pointing away from the Power Head


Ch attaCh Rail StRap to eND
Rail SeCtioN
Assembly Step 4:
A Attach Rail Strap to End Rail Section with 2 (1/4”-20) Hex
Head Bolts and 2 (1/4”-20) Serrated Flange Hex Nuts
(Figure 13)
B Tighten snugly but Do Not over-tighten


Ch aliGN Rail SeCtioNS aND
tiGhteN all boltS
Assembly Step 5:
A Align all Rail Sections so Magnetic Carriage Assembly can
slide freely along length of Rail
B Securely tighten all fasteners now. Do Not over-tighten


Ch iNStall aND CoNNeCt limit
SwitCheS
Assembly Step 6:
A Turn Opener right side up and support Power Head to avoid
damaging the Light Bulb Sockets
B Uncoil Limit Switch Wires and retain Twist Ties
C Place Switches on Rail with arrows pointing away from
Power Head (Figure 14)
D Place Close Limit Switch (Brown Wire) 15” from Rail Strap
Insert (#8-32 x 1”) Hex Head Screw into Switch hole and
finger-tighten until later
E Place Open Limit Switch (White Wire) 15” from Power Head
Insert (#8-32 x 1”) Hex Head Screw into Switch hole and
finger-tighten until later
opeN GReeN paRtS baG
Magnetic
Carriage
Assembly
Released
Toward Power Head
Toward door
and header
Engaged
End Rail Section
Figure 12 Slide Magnetic Carriage onto Rail
Rail Strap
End Rail Section
Figure 13 Attach Rail Strap
Wire Clips
#8-32 x 1”
Hex Head Screws
White
Wire
Open Limit
Switch Assembly
Brown
Wire
Close Limit
Switch Assembly
Hardware (green bag)
Figure 14 Install Limit Switches on Assembled Rail
Open Limit
Switch
(White wire)
Close Limit
Switch
(Brown wire)
Arrows point
toward door
#8-32 x 1”
Hex Head
Screws
Wire
Clip
Carriage
Stop
Emergency
Release Knob
11
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
NOTE
• Loosen (Do Not Remove) Terminal Block Screws
• Limit Switch adjustments and securing the Wires
will be done later
F Lay Wires in channel on top of Rail and secure with Wire Clips
(Figure 14)
G Coil and bundle excess Limit Switch Wires on top of Power
Head with Twist Ties Leave just enough Wire to reach
Terminals on back of Power Head (Figure 14)
H Turn Opener upside down, and connect Limit Switch Wires to
Power Head Terminal Block (Figure 15):
• Terminal 4: OPEN Limit Switch Wire (white)
• Terminal 5: OPEN Limit Switch Wire (white) and
CLOSE Limit Switch Wire (brown)
• Terminal 6: CLOSE Limit Switch Wire (brown)
Magnetic
Carriage
Assembly


Ch ReCoRD opeNeR moDel
aND SeRial NUmbeR
Assembly Step 8:
Please note the following information so it is available if you need
to call us:
Date purchased: ________/________/________
Serial number (Figure 17): _________________________
Remote Control Model: _________________________
Model number (Figure 17): _________________________
Dealer Name: _________________________
Dealer Address: _________________________
City: _________________________
State: _________________________
Zip: _________________________
Phone: _________________________
NOTE
Please keep original or photocopy of your sales receipt with
this manual for future reference should service ever be
required
Antenna
Figure 15 Connect Limit Switch Wires to Power
Head Terminal Block
Terminal
Block
White Limit
Switch wires
Brown Limit
Switch wires
Serial
Number
(example)
Model
Number
Figure 17 Model and Serial Numbers


Ch attaCh emeRGeNCy
ReleaSe CoRD aND kNob
Assembly Step 7:
• Tie overhand knot at one end of emergency release cord and pull
cord through the hole in the release lever up to the knot
(Figure 16)
• Thread opposite end of cord through knob and tie a knot in this
end also
• Following installation of your garage door opener, adjust the
height of the knob to no less than 6 feet above the floor
* The Emergency Release Cord is threaded through the Carriage release
lever at the factory
Figure 16 Attach Emergency Release Cord and
Knob
12
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
GaRaGe DooR opeNeR iNStallatioN
NOTE
For lightweight garage doors, make sure you have installed
the proper reinforcement (See Check Door Condition and
Thickness on page 3)


Ch iNStall heaDeR bRaCket
Installation Step 1:
A If needed, attach a 2” x 6” board (Figure 18) (also see page 4)
with at least two (four is recommended) Lag Screws and Flat
Washers (not supplied)
B Attach Header Bracket to header at mark above door

• Mark 3 hole positions
• Drill 3 (5/32”) pilot holes
• Attach Header Bracket with 3 (1/4” x 2”) Lag Screws

CAUTION
• The Header Bracket must be fastened to the garage
framing Do Not fasten the Header Bracket to drywall,
particle board, plaster, or other such material
• It may be necessary to attach a 2” x 6” board across the
wall studs above the door header to serve as a
mounting plate for the Header Bracket The Bracket can
then be mounted at the proper location and have
sufficient support
• If a door spring is in the way, place the Header Bracket
above the spring Do Not move the door spring
opeN oRaNGe paRtS baG
NOTE
Mounting variations are shown in Figure 17 Any of these
may be used depending on space However, it is critical that
the point where the Rail attaches to the Header Bracket be
on the center line of the door
Mount directly
into header
Figure 18 Attach Header Bracket above Garage Door
Use of Header Bracket
support board
Center Line of door Center Line of door
Bottom of
bracket flange

5/16-18 x 3/4”
Hex Head Bolts
Header
Bracket
1/4” x 2”
Lag Screws
Hardware (orange bag)
5/16-18 x 3/4”
Hex Serrated Flange Nuts
Door Bracket
1/4”-20 x 3/4”
Self-Drilling Screws
Highest Point of door travel
+ 2-1/2” (sectional door) or
+ 6” (one-piece door)
13
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch iNStall GaRaGe DooR
bRaCket
Installation Step 2:
For sectional doors:
A Place Door Bracket on door center line, no lower than top
roller, and mark holes (Figure 19)
B Attach Door Bracket:
• For metal doors, use 3 (1/4” -20 x 3/4”) Self-Drilling
Screws (provided)
• For wood doors, use 3 (1/4” x 2”) Lag Screws or
3 (1/4” x 1-1/4”) Lag Screws (not provided)
NOTE
Before installing, check length of the included Lag Screws vs
the thickness of your garage door For doors thinner than 2”,
use 1-1/4” Lag Screws Check door condition and thickness
See page 3

CAUTION
Doors made of masonite, lightweight wood, fiberglass, metal,
or other lightweight materials must be properly braced
before mounting door Opener
For one-piece doors:
A Position Door Bracket on door’s center line, as high as
possible or on top of door
B Attach Door Bracket:
• For metal doors, use 3 (1/4” -20 x 3/4”) Self-Drilling
Screws (provided)
• For wood doors, use 3 (1/4” x 2”) Lag Screws (provided)


Ch attaCh Rail to heaDeR
bRaCket
Installation Step 3:
A While supporting the Power Head, place threaded end of Rail
Strap Bolt through Header Bracket hole (Figure 20)
B Attach (5/16”-18) Flange Nut to Rail Strap Bolt
Finger-tighten until later
SECTIONAL DOORS ONE-PIECE DOORS
Center Line of door Center Line of door
Attach no
lower than
top rollers
Attach at
highest point
on door
Optional Door Operator Bracket (not included)
Figure 19 Attach Door Bracket
Rail
Strap
Rail Strap Bolt
Header Bracket
Figure 20 Attach Rail Strap to Header Bracket
14
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch attaCh poweR heaD to
GaRaGe
Installation Step 4:
A Raise and support Opener Power Head (along door center
line) higher than highest point of door travel (using step
ladder, etc) (Figure 21)
B Measure distance from Opener to garage ceiling
C Install Mounting Straps and/or support brackets (angle iron
not included) to joists or trusses and to mounting slots in
Opener Use (5/16”-18 x 3/4”) Hex Head Bolt, (5/16”-18)
Serrated Flanged Nut, and (1/4” x 2”) Lag Screws as needed
(Figure 22)
D Securely tighten all fasteners now Do Not over-tighten
NOTE
• Make sure the rail of your supported Power Head is
slightly higher than the highest point of door travel
by raising the door to check Adjust as needed
• Materials needed for mounting Opener Power Head
to garage may vary Read all instructions completely
• Garage constructions differ Extra material may be
needed See Check Power Head Mounting Area on
page 5

CAUTION
Mounting Brackets must be fastened to garage framing
Do Not fasten to drywall, particle board, plaster, or other
such materials
SECTIONAL DOORS
Rail Should be level or dip down slightly
Check for clearance
ONE-PIECE DOORS
Set clearance at 1”-1
1
/2” between Rail and door at
highest point of travel
Figure 21 Checking Power Head position
Perforated
Angle Iron
OPEN BEAM CEILING EXAMPLES
Figure 22 Mounting methods for open beam and finished ceilings
Mounting Straps Support board added
for longer spans
(Angle iron not included)
FINISHED CEILINGS
Locate ceiling joists or
trusses using
a stud finder
or similar
device
Attach angle iron
(not included) to
joists or trusses
through finish material
using Lag Screws
15
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch aSSemble aND CoNNeCt
DooR aRmS
Installation Step 5:
For sectional doors:
A Attach Curved Door Arm to Door Bracket with Clevis Pin and
Cotter Pin (Figure 23A)
B Attach Straight Door Arm to Magnetic Carriage Assembly
C Attach both Arms together with 2 (3/8” x 7/8”) Hex Head
Bolts and 2 (3/8”) Serrated Flange Hex Nuts so overall length
is as short as possible Securely tighten fasteners
D Adjust height of Emergency Release Cord Knob to 6’ above
floor:
• Pull Cord through Magnetic Carriage Assembly Lever
until Knob is 6’ from floor.
• Tie a new overhand knot in Cord at Magnetic Carriage
Assembly Lever
For one-piece doors:
A Attach Straight Arm to Door Bracket with Clevis Pin and
Cotter Pin (Figure 23B)
B Attach Curved Arm to Magnetic Carriage Assembly
C Attach both Arms together with 2 (3/8” x 7/8”) Hex Head
Bolts and 2 (3/8”) Serrated Flange Hex Nuts so overall length
is as long as possible Securely tighten fasteners
D Adjust height of Emergency Release Cord Knob to 6’ above
floor:
• Pull Cord through Magnetic Carriage Assembly Lever
until Knob is 6’ from floor.
• Tie a new overhand knot in Cord at Magnetic Carriage
Assembly Lever
opeN yellow paRtS baG

WARNING
Do Not skip Step D above!
Failure to comply may leave Emergency Release Knob within
reach of children. If the Knob is pulled with garage door fully
or partially open, garage door may close without warning!
Safe-T-Beam® (STB) Brackets
Clevis Pins Cotter Pins
3/8” x 7/8”
Hex Head Bolts
#10-16 x 1
1
/4”
Phillips Hex Head Screw
3/8” Hex Serrated
Flange Nuts
Hardware (yellow bag)
As short as
possible
Straight
Door Arm
Curved
Door Arm
Figure 23A Assemble Arms (SECTIONAL)
As long as
possible
Straight
Door Arm
Curved
Door Arm
Figure 23B Assemble Arms (ONE-PIECE)
16
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch iNStall Safe-t-beam®
SyStem
Installation Step 6:
A Install Safe-T-Beam® Source and Sensor (Figure 24):
• Mark both sides of garage door frame or wall 6”
above floor
• Hold Bracket against door frame or wall Check if Bracket
extends out from wall far enough so tongue of Bracket is
beyond door, tracks, or any door hardware If not, Safe-T-
Beam® Mounting Bracket Extensions are available from a
Genie Factory Authorized Dealer or through the
Accessories Order Form
– Blocks of wood, etc may be substituted
for extensions
• Position top of Mounting Bracket at 6” mark and fasten
with 2 (#10-16 x 1-1/4”) Phillips Hex Head Screws
per Bracket
B Attach Safe-T-Beam® Source (Red LED) and Sensor (Green
LED) to Brackets (Figure 24):
• For single-door garages
– Determine which side of garage receives the most
direct sunlight, and place Source (Red LED) on this
side whenever possible
• For multiple-door garages see (Figure 25)
– Preventing crossed signals is critical
– Place Source and Sensor modules on adjacent doors
facing in opposite directions
• Slide the Safe-T-Beam® Source and Sensor onto the
tongues of the Brackets until they click into place
• Check final height of Lens (Figure 26)
ELECTRICAL WARNING
Ensure there is No power to the Opener before installing
Safe-T-Beam® System Wires If Opener is plugged into outlet,
Unplug it now
NOTE
The Opener will not close the door automatically unless the
Safe-T-Beam® System is installed
NOTE
Mounting Brackets can be attached to brick walls or concrete
floor using masonry anchors (not included)
NOTE
To help prevent interference from the sun, the Safe-T-Beam®
Sensor (Green LED) may be placed further away from the
door opening, where it will spend more time in the shadows
Safe-T-Beam® Sensor
(Green LED)
Safe-T-Beam® Source
(Red LED)
Slide onto
tongue of
Bracket until
it clicks into
place
Figure 24 Install Safe-T-Beams®
SuN
ONE DOOR
GARAGE
ThREE DOOR
GARAGE
RED
LED
RED
LED
GREEN
LED
RED
LED
GREEN
LED
GREEN
LED
GREEN
LED
RED
LED
RED
LED
RED
LED
GREEN
LED
GREEN
LED
TWO DOOR
GARAGE
Figure 25 Source/sensor Locations
Top edge of Lens
5” - 6” above floor
Figure 26 Final Check Safe-T-Beams®
Top of
Bracket
6” above
floor
RED LED = Source (transmitter)
GREEN LED = Source (receiver)
17
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
C Install Safe-T-Beam® Wiring (Figure 27):
• Route Wire and Insulated Staples
(Figure 28 and Figure 29)
– Securely fasten Wires with Insulated Staples as
you go Staples should be snug only
– Wires between garage wall and Power Head should
be run on top of Rail and underneath Wire Clips
• Attach Wires to Safe-T-Beam® Sensors
– Split and strip Wire ends to be connected as shown
– Loosen Terminal Screws
– Insert each Wire under flat plate and tighten Screw
It does not matter which Wire, white or striped, goes
on which Terminal
• Attach Wires at Power Head
– Wires are connected to Terminals #2 and #3 on
Power Head Terminal Block It does not matter which
Wire, white or striped, goes on which Terminal
• Check the following
– Ensure that no part of door or its hardware is in path
between Source or Sensor Lenses
• Ensure that tops of Lenses are between 5” – 6” above
floor Brackets are flexible and can be adjusted slightly
if needed
CAUTION
Staples which are too tight may cut or pinch Wires Cut or
pinched Wires can cause the Safe-T-Beam® System to stop
working When installing the Insulated Staples, make sure
you fasten them only as tightly as needed to hold the
Wire securely
NOTE
The Safe-T-Beam® alignment check will be performed
following connection to electrical power
Do Not plug in yet!
opeN ReD paRtS baG
Insulated Staples
(approximately
30 parts)
Figure 27 Wire the Safe-T-Beam® System
#6-1
1
/4”
Pan Head
Screws
Hardware (red bag)
Wire
Approx
1
1
/2”
Strip
approx
1
/2”
Wire Clips
Insulated
Staples
Terminal
attachments
at Safe-T-Beam®
Terminal
attachments
at Power Head
Allow slack for
adjustment
Figure 28 Wiring Method A
Wire Clips
Insulated
Staples
Terminal
attachments
at Safe-T-Beam®
Terminal
attachments
at Power Head
Allow slack for
adjustment
Figure 29 Wiring Method B
Wall
Button
18
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch wall CoNtRol
iNStallatioN
Installation Step 7:
A Wall Console (Figure 30):
• Has a Security Vacation Lock Switch which disables
all controls
• LED Indicator shows whether system is powered, locked,
or unlocked Makes Console easy to find in dark
• Controls door Opener from inside garage
• Independent Light Control allows convenient manual
control of Opener Lighting System
B Find a convenient mounting location:
• Within direct sight of garage door
• At least 5’ above floor (to prevent small children from
operating garage door)
• Away from any moving garage door or Opener parts (you
should not be able to reach door while standing at
Wall Controls)
C Ensure Vacation Lock Switch is in UNLOCKED position.
D Wire Wall Controls to Opener (Figure 31):
• On Power Head, connect Striped Wires to Terminal #1 and
White Wires to Terminal #2
• On back of Wall Controls, connect Striped Wire to
terminal “B” and White Wire to Terminal “W”
E Attach Wall Controls onto wall at locations found above with 2
(#6 x 1-1/4”) Pan Head Screws
F Remove protective backing from Entrapment Warning Label,
and attach it to wall near Wall Console

WARNING
Verify there is no power to the Opener before installing Wall
Console Wires
NOTE
More than one lighted Wall Control per Opener will cause
a malfunction

CAUTION
• Use of any wall consoles other than the type included
will prevent the light from working properly and could
cause the door to operate on its own
• Cut or pinched Wires can cause the Wall Console to stop
working When using the Insulated Staples, be sure to
only tap them in as far as needed to hold the
Wire snugly
Security
Vacation
Lock
Switch
Independent
Light Control
Garage
Door
Control
Wall Console
Figure 30 Wall Control
58 B
W
Allow
slack
Terminal
Attachment
at Power Head
White Wire
to
Terminal 2
Striped Wire
to
Terminal 1
Terminal
Attachment
at Wall Console
White Wire
to
Terminal ”W”
Striped Wire
to
Terminal “B”
Figure 31 Install Wall Control with
Entrapment Warning Label
OR 58
19
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch CoNNeCtiNG poweR
Installation Step 8:
A Check building codes:
• If building code requires Opener be permanently wired
to building, have a licensed electrician perform step B
• If you are not installing permanent wiring, go to step C
B Instructions for licensed electrician - connecting power
with permanent wiring (Figure 32):
• Remove power from circuit
• Remove Motor Cover
• Remove and discard Power Cord
– Cut off Power Cord inside Power Head as near Strain
Relief as possible
– Remove Knock-Out Plug, Strain Relief, and Power
Cord (Cut Ground Wire on line side of Toroid)
– Dispose of Plug, Strain Relief, and Power Cord
• Install required entrance bushing
• Connect permanent wiring to Power Head Wires
– White supply line to Opener White Wire
– Black supply line to Opener Black Wire
– Ground to Opener Green Wire
– Replace Motor Cover
– Restore Power to circuit
C Connecting Power with Plug:
• Plug Opener into a grounded outlet as stated in previous
electrical warning
D Perform Safe-T-Beam® alignment check:
• Check if Safe-T-Beam® Source Red LED is glowing
continuously (OK) or blinking (problem).
• If Red LED is blinking twice, adjust Sensor Brackets as
needed to make Red LED glow continuously (Refer to
page 26)

ELECTRICAL WARNING
• To reduce the risk of electrical shock, this equipment has
a grounding type Plug that has a third (grounding) Pin
This Plug will only fit into a grounding type outlet If the
Plug does not fit into the outlet, contact a qualified
electrician to install the proper outlet Do Not change
the Plug in any way The door Opener must be properly
grounded to prevent personal injury and damage to the
components
• The electrical power to the door Opener Must Be removed
when the Motor Cover is removed Electrical power must
remain off while making electrical connections
NOTE
• Use only Underwriters Laboratories, Inc (UL)
recognized wire nuts
• The Circuit Boards are light sensitive Ensure the
Motor Cover is installed before energizing
the Opener
Figure 32 Connecting power with permanent wiring
Cut
Wires
here
Knockout
Two
tabs
slide
out
Four screws hold
Motor Cover
20
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch Set limit SwitCheS aND
foRCe CoNtRolS
Installation Step 9:
Coarse Setting of Limit Switches
A Setting Close Limit Switch (Figure 33):
• Check that Magnetic Carriage Assembly is disengaged
• With garage door fully closed, slide Close Limit Switch
until it is aligned with Carriage Assembly Magnet
• Tighten Set Screw Do Not over-tighten
B Setting Open Limit Switch:
• Manually open garage door to full open position
• Slide Open Limit Switch until it is aligned with Carriage
Assembly Magnet
• Tighten Set Screw Do not over-tighten
• Re-engage Magnetic Carriage Assembly
Setting Force Controls and Final Adjustment of Limit
Switches
A Pre-set Force Controls to midpoint between fully counter
clockwise and fully clockwise (Figure 34)
B Adjust the Close Limit Switch:
• Press Wall Console to close garage door
– If door does not close completely, measure distance
from bottom of door to floor Move Limit Switch
same amount toward door and try again
– If door reverses after contacting floor, move Limit
Switch toward Power Head and try again
– If door reverses before contacting floor, increase
Close force and try again
– If door fails to move, check Safe-T-Beam® System See
Safe-T-Beam® Troubleshooting Guide on pg 26, and
Opener System Self-diagnostic Troubleshooting
on pg 27
• Tighten Limit Switch Set Screw Do not over-tighten
(strip) Limit Switch Set Screw
C Adjust Open Limit Switch:
• Press Wall Console to open garage door
– If door does not open completely, move Limit Switch
toward Power Head
– If door opens completely, but motor continues to
run, move Limit Switch toward door
• Tighten Limit Switch Set Screw Do not over-tighten
(strip) Limit Switch Set Screw.

WARNING
• The garage door opens rapidly, and can cause serious
injury or death
• Keep the path clear.
• Position the ladder to the side of the Power Head so it is
clear of all moving parts of the Opener and the door
• Set the door Opener to use the minimum force needed
to open the door
NOTE
• Little effort is required to turn the Force
Adjusting Knobs.
• If the door stops moving while opening or
closing, adjust the Open Force or Close Force
Controls slightly clockwise (to slightly
increase the force) and retry the step
• The Open Force and Close Force Controls are to
be set to the minimum force necessary to
ensure the door smoothly opens fully and
closes completely
• The garage door will move slowly the first
time it runs, until the Opener “learns” the
type of door
• Ensure the Magnetic Carriage Assembly is
engaged and is between the two Limit
Switches before operating the Opener
Close Limit Switch
(door fully closed)
Carriage
(disengaged)
Magnet
Switch
Switch
Magnet
Open Limit Switch
(door fully open)
Carriage
(disengaged)
Figure 33 Setting Limit Switches
Force Controls
Figure 34 Making Force Adjustments
21
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
D Test Door Opener:
• Run door up and down a few times using Wall Console
and observe door travel
• Repeat steps above as needed to set Limit
Switch positions
E Adjust Open Force to minimum needed:
• Place door in closed position using Wall Console
• Gently adjust Open Force fully counterclockwise
(minimum force)
• Run Opener using Wall Console
• Observe that door runs to Open Limit Switch
– If not, adjust Open Force Control slightly clockwise,
close garage door, and open it again
• Repeat steps above until garage door runs smoothly
from Close Limit Switch to Open Limit Switch
F Adjust Close Force to minimum needed:
• Place door in open position using Wall Console
• Gently adjust Close Force fully counterclockwise
(minimum force)
• Run Opener using Wall Console
• Observe that door runs to Close Limit Switch
– If not, adjust Close Force Control slightly clockwise,
open garage door, and close it again
• Repeat steps above until garage door runs smoothly
from Open Limit Switch to Close Limit Switch
A Open garage door using Wall Console
B Lay a 2” x 4” board flat in center of doorway
C Close door using Wall Console
D Check that door stops and reverses within 2 seconds after it
contacts board:
• If door does not reverse, decrease Close Force until
door reverses
• If door still does not reverse, move Limit Switch
toward door
E Check Safe-T-Beam® System operation:
• If beam is blocked, door will not close.
NOTE
• To protect your new investment, your Excelerator® is
equipped with a Timer and Cycle Counter which work
together to prevent any chance of heat damage to
electrical circuits caused by too many cycles in too short
a time If your Opener suddenly stops responding to the
Wall Console - Do Not Unplug the Unit - simply wait
10 minutes for the Timer/Cycle Counter to reset itself
and try again
• Unplugging the unit will prevent the Timer/Cycle
Counter from resetting
NOTE
The door must contact the 2” x 4” board before the
Carriage activates the Close Limit Switch If not,
readjust the Close Limit Switch


Ch
SettiNG CoNtaCt

ReveRSe fUNCtioN
Installation Step 10:
NOTE
Limit Switch and Force Adjustments must be completed
before checking the contact reverse function (Figure 35)
2” x 4” board
laid flat
Figure 35 Checking Contact Reverse
22
For Help, call 1-800-35-GENIE or visit www.geniecompany.com


Ch pRoGRammiNG the
Remote CoNtRol
Installation Step 11:
A To program one Button of a Remote Control (Figure 37):
• Locate Learn Button and Learn Indicator Light near
Terminal Block on Power Head (Figure 38)
• Press and release Learn Button Red Learn Indicator
Light will blink 2 times per second
• Press Remote Control Button once within 30 seconds
Red Learn Indicator Light will stay lit
• Press Remote Control Button again Red Learn Indicator
Light will go out, indicating that memory is stored
B Program each additional Remote using step A above
aCCeSSoRieS
To Erase All Remotes from Power Head Memory
A Press and hold Learn Button on Power Head for 10 seconds
or until Learn Indicator Light goes out Memory is erased:
• Program Receiver again as needed
To Replace Remote Control Battery
A Push in on Battery Cover Latch at base of Remote Control
(Figure 39):
• Use coin, pen, screwdriver or any similar device
– Cover snaps open
• Replace old Battery with new A23,
12 Volt Battery
B Snap Battery Cover closed
Remote Control Operation
A Press Button on Remote Control Garage door will move
B Press Button again Garage door will stop:
• The door automatically stops at the end of the open or
close cycle
C Press Button again Garage door will reverse

WARNING
A moving garage door may cause serious injury or death
• Keep people clear of opening while door is moving.
• Do not allow children to play with the Remote Controls
If the Safety Reverse does not work properly:
• Close the door and disconnect the Opener using the
Emergency Release Cord
• Do not use the door Opener, Remote Controls, or
Wireless Keypad.
• Refer to the door and door Opener Owner’s Manuals
before attempting any repairs
NOTE
• Each Remote Control must be programmed
separately
• The Remote Controls will not cause the door
Opener to close the garage door if the Safe-T-
Beam® System is malfunctioning
• When programming the Remote Controls, they
must be at least 24” from the Antenna Wire
• If the red Learn Indicator Light blinks
approximately 4 times per second,
programming has stopped If programming
has stopped, repeat the above steps
• Each Button on a 2 or 3 Button Remote Control
is for a different Opener You cannot use more
than one Button per Remote, per Opener
• A maximum of seven Remote Controls or
Wireless Keypads can be stored into the
Receiver at one time If a Remote Control
becomes lost, or if you want to delete a Remote
Control or Wireless Keypad, see “To Erase All
Receiver Memory”
1 Button
Remote
2 Button
Remote
3 Button
Remote
Figure 37 Genie Remote Controls
Learn Code Button
Figure 38 Learn Code Button and Indicator Light
Visor Clip
Model
Number
Push to open
Battery Cover
Figure 39 Remote Control Battery Replacement
23
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
A Monthly:
• Door springs and door hardware:
– Oil door roller, bearings, and hinges using silicone
lubricant or light oil
• Balance Door
– Close door
– Release Magnetic Carriage Assembly from Rail Assembly
by pulling down on Emergency Release Knob.
– Raise door manually 3’- 4’ and verify that door stays at
that position See Check Step 2 on page 3
– Reattach Magnetic Carriage Assembly to Rail Assembly by
pulling the Emergency Release Knob toward Power Head
– Close door
• Contact Reverse Test.
– Perform Installation Step 10 on page 21
B Yearly:
• Wipe off old excess lubricant from Drive Screw
• Lubricate Drive Screw with Genie Lubricant (GLU-3)


iNStall liGht bUlbS
aND leNS
Installation Step 12:
A Install two 60 Watt light bulbs (not included) into Light
Sockets (Figure 39):
• Rough service, 130 Volt bulbs are recommended
B Install Lens into slots in Motor Cover
C Install Genie Emergency Release Kit (GER-2) accessory,
if purchased
D Installation is now complete
NOTE
When the door is 3’ - 4’ above the ground, the door
should stay open Slight movement is acceptable If
the door moves too much, contact a Genie Factory
Authorized Dealer for service or call Customer Service at
1-800-35-GENIE.

WARNING
Do not operate door automatically or manually if springs
are broken Contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE
Lens
1A
Snap Lens Hinges into
slots on back of Motor Cover
60 Watts
maximum
Push in
Latches
to
close Lens
Figure 39 Install Lens Cover and Light Bulbs
Transmitter Compliance Statement
MAINTENANCE

WARNING
If the door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit
Switches and Force Controls on page 20 If the Opener
still fails, contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE
NOTE
Use ONLY Genie Lubricant (GLU-3) Other lubricants
may damage the Opener
FCC AND IC CERTIFIED
All devices comply with Part 15 of the FCC Rules
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation

GLU-3
Lubricant
24
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
WARNING
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH
1 READ AND FOLLOW ALL INSTRUCTIONS
2 Never let children operate or play with the Door Controls. Keep the Remote Control away from children.
3 Always keep the moving door in sight and away from people and objects until the door is completely closed
NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR
4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR
5 Test Opener monthly The door MUST reverse on contact with a 1-1/2” high object (or a 2” x 4” board laid flat)
at the center of the doorway on the floor After adjusting either the Force or the Limit of travel, retest the Door
Opener Failure to adjust the Opener properly may cause severe injury or death
6 When possible use the Emergency Release only when the door is closed Use caution when using this Release
with the door open Weak or broken springs are capable of increasing the rate of door closure and increasing
the risk of severe injury or death
7 KEEP GARAGE DOORS PROPERLY BALANCED. See Owner’s Manual. An improperly balanced door increases the
risk of severe injury or death Have a Genie Factory Authorized Dealer make repairs to cables, spring
assemblies, and other hardware
8 SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Use the Wall Console included with Opener Any other wall console can cause the Opener to operate unexpectedly and
the light to stop working
tRoUbleShootiNG GUiDe
Safe-T-Beam® System Self-Diagnostic Troubleshooting
Source (Red LED) Sensor (Green LED) Possible Problem Solution
ON ON Normal operation None required
OFF OFF
• Power Head not powered • Check breakers, fuses, plugs
• Wiring from Power Head bad • Check wiring for obvious shorts

OFF ON
• Wiring to Source missing or bad • Check wiring
• Power has been interrupted • Remove power and reapply
2 BLINKS, Pause • Beam not aligned • Check Source, Sensor alignment
(Repeat) ON • Beam obstructed • Check for obstruction
• Sensor defective • Contact Customer Service
2 BLINKS, Pause • Wire to Sensor missing or bad • Check wiring
(Repeat)
OFF
• Sensor defective • Contact Customer Service
3 BLINKS, Pause • Sensor receiving interference • Determine source of interference
(Repeat)
ON
• Contact Customer Service
4 BLINKS, Pause • Source not sending pulses • Contact Customer Service
(Repeat)
ON
• Source defective • Contact Customer Service


25
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Opener System Self-Diagnostic Troubleshooting
• SeeStatusLightonFigure38,page22)
You See Problem What to Do Reference
1 BLINK, Motor Drive • Reset Opener—unplug (or disconnect power), wait 5 seconds, plug
Pause Board back in (reapply power), and activate from Wall Console
(Repeat) Interrupt
Normal • First Cycle will run at slow speed
operation
restored
If the problem • Check door condition NOTE: This Opener is equipped with an See Door
recurs automatic garage door balance detection system. An improperly Safety Guide
balanced door, damaged or worn counter-balance spring, binding
door hardware or rollers may result in a “ONE-BLINK” signal.
• Contact Customer Service for further assistance
Operation not • Check door condition 1 See page 3
restored • Have a Genie Factory Authorized Dealer check: 2 See door
– Fuse on Motor Drive Board Safety Guide
– Ribbon Cable on Motor Drive Board is properly inserted into
Connector on Controller Board
• Contact Customer service for further service
2 BLINKS, Controller • Reset Opener — unplug (or disconnect power), wait 5 seconds, plug
Pause Board back in (reapply power), and activate from Wall Console
(Repeat) Interrupt • Have a Genie Factory Authorized Dealer check that Ribbon Cable on
Motor Board is properly inserted into connector on Controller Board
• Contact Customer Service for further assistance
3 BLINKS, Opener • DonotunplugordisconnectpowerfromOpener.Wait10minutes
Pause Overheated for internal clock to provide additional cycles. Cycles are restored
(Repeat) or at a rate of 5 cycles per 10 minutes of rest.
Over-cycled • ContactCustomerServiceforfurtherassistance.
4 BLINKS, Force Settings • Check Force Settings NOTE: Force Settings are not pre-set at factory. 1 See page 20
Pause Incorrect • Check door condition 2 See Door
(Repeat) • Contact Customer service for further assistance Safety Guide
5BLINKS, Safe-T-Beam® • Check Safe-T-Beam® Self-diagnostic System NOTE: Safe-T-Beam® See page 16
Pause Malfunction System must be installed and operational to enable door to close.
• Contact Customer Service for further assistance
6 BLINKS, Wall Console • Check Wall Console Wiring for shorts, tight Staples, or pinched Wires See page 18
Pause does not work • Check Wiring Connections at Power Head and Wall Console
(Repeat) • Contact Customer Service for further assistance
7 BLINKS, Limit Switches • Check Limit Switch Wire connections to Terminals on Power Head See page 20
Pause not working • Check for shorted or pinched Wires under Limit Switch Brackets
(Repeat) • Contact Customer Service for further assistance
8 BLINKS, Wall Console • Vacation Locking Switch on Wall Control is in “Lock” mode See page 18
Pause locked Unlock switch
(Repeat) • Contact Customer Service for further assistance
NOTE
• The status LED Indicator Light is located under the Lens Cover. The Green LED light will turn ON, then OFF when
power is applied to the Opener If LED stays ON, have a Genie Factory Authorized Dealer check the Controller
Board, or call Customer Service at 1-800-35-GENIE
• If Safe-T-Beam® problems exists, the door can be closed electrically by holding the Wall Console Button down
until door is fully closed
• The Remote Controls and Wireless Keypad will not work without a working Safe-T-Beam® System.
26
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
General Troubleshooting (Always Check the Status LED Light)
Problem What To Do
Opener does not run 1 Check power source
from Remote Control A If Opener is connected to an outlet

:
• Plug a working lamp into outlet used for Power Head
• If lamp glows, power source and outlet are OK.
• If not, check fuse or circuit breaker or non-compatible GFCI
NOTE: A licensed electrician must replace non-compatible GFCI’s.
B If Opener is connected to a wiring box:
• Check that fuse is not blown, or circuit breaker is on and not tripped or off
• If still no power, have a licensed electrician check circuit and wiring
2. If Power Source is OK

:

Check connections at Power Head Terminals (see Wall Console Installation page 18), tighten any loose connection

Check connections at Wall Console Terminals, tighten any loose connections
Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive
Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-35-GENIE
Door Opener starts • Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires)
for no apparent reason Replace any shorting Staples and shorted Wires
• Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory
and reprogram for remaining remote controls (See Erase All Receiver Memory on page 22)
• Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls
Door starts down, then • Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 20)
stops before it is Adjust as needed
completely closed • Check for shorted Wires
• Check garage door for binding
Door starts down, then • If a new installation, check Door Arm position
stops and goes back up • Check operation of Contact Reverse function
• Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses
• Check Safe-T-Beam® System diagnostic code
• Check Close Force adjustment (see Set Limit Switches and Force Controls on page 20) Adjust as needed
• Check garage door for binding
Door will only run closed • Check Open Limit Switch for a short circuit and for proper wiring
• Check Open Force adjustment (see Set Limit Switches and Force Controls on page 20) Adjust as needed
• Check condition of garage door and door spring(s)
• WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie
Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE
Door will only run open • Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart
(see Safe-T-Beam® System Self-diagnostic Troubleshooting Section on page 24)
• Check Close Limit Switch for a short circuit and for proper wiring
• Check Close Force adjustment (see Set Limit Switches and Force Controls on page 20) Adjust as needed
Lights will not go out • Disconnect Wires connected to Wall Console (see Wall Console Installation on page 18)
Check their condition and either replace or reconnect
• Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls
or Wireless Keypad to operate Opener.

Door starts up, but stops • Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly
before it is balanced as detailed in Maintenance Section
completely open • WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie
Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE
• Check Open Limit Switch for a short circuit and for proper wiring
• Check Open Force adjustment (see Set Limit Switches and Force Controls on page 20) Adjust as needed
Operator runs, but door • Ensure Magnetic Carriage Assembly is engaged to Rail Drive Screw (see Install Magnetic Carriage Assembly
does not move onto Rails on page 10)
• Check Force adjustment (see Set Limit Switches and Force Controls on page 20) Adjust as needed
• Check that all sections of Rail Drive Screw are turning when Motor runs If not:
– Check condition (not cracked, split, or broken) and placement of Coupler Replace as needed
– Check condition (not cracked, split, or broken) and placement of Collar and Clip Replace them
as needed
Wall Console Vacation • Ensure Magnetic Carriage Assembly is in contact with Close Limit Switch
Lock function does • Check when door is fully closed, that Carriage activates Close Limit Switch If not, adjust position of Close
not work Limit Switch (See page 19)
27
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
General Troubleshooting (Always Check the Status LED Light)(Continued)
Problem What To Do
Remote Control has less • Relocate Remote Control inside car
than 25’ operating range • Ensure Remote Control is pointing toward garage door when pressing Control Button
• Replace Remote Control Battery type “A23” (See page 22)
• Reposition Opener Antenna Wire
• Do Not attempt to retune Remote Controls or Receiver
Opener works from Wall • Program code for each Remote Control into Receiver memory (See Programming the Remote
Control, but not from Control on page 22
Remote Control • Replace Remote Control Battery type “A23” (See page 22)
• Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses
• Check Safe-T-Beam® System for any diagnostic codes If present, troubleshoot as detailed in
Safe-T-Beam® System Self-Diagnostic Troubleshooting Chart (See page 24)
Noisy operation • Ensure all fasteners are tightened
• Check that the garage door and Opener are in good repair, properly lubricated, and properly
balanced (See Maintenance page 23)
• WARNING: If you suspect a problem with garage door hardware or springs, contact a Genie
Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE.
Safe-T-Beam® System • If an operational problem exists, Opener will not run closed
• Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses
• Check Safe-T-Beam® System for any diagnostic codes If present, troubleshoot as detailed in Safe-T-Beam®
System Self-Diagnostic Troubleshooting Chart (See page 24)
Door closes, and Opener • Check position of Wall Console Vacation Lock Switch. It must be in UNLOCKED position for Opener to
shuts down open door


MOTOR
WHÌTE
WHÌTE
W
H
Ì
T
E
B
R
O
W
N
B
R
O
W
N
S
T
R
Ì
P
E
Y
E
L
L
O
W
GREEN
O
R
A
N
G
E
WHÌTE
WHÌTE
BLUE
BLACK
GREEN
WALL CONTROL
OPEN LÌMÌT
CLOSE LÌMÌT
CONTROLLER BOARD MOTOR DRÌVE BOARD
PRÌMARY GROUND
LÌGHTS
(60 WATTS MAX.)
LÌNE
PLUG

WARNING
Opening Cover May Result in Electric Shock
wiRiNG DiaGRam
28
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
the GeNie CompaNy limiteD waRRaNty
What is Covered
Any defect in material and workmanship from personal, normal
household use in accordance with the Owner’s Manual
For How Long:
H8000D Series — Lifetime* on motor, on parts and service
ISD990 Series — Lifetime* on motor, 5 years* on parts
ISD990-2 Series — Lifetime* on motor and all parts
ISD995 Series — Lifetime* on motor and all parts
ISD995-2WKM Series — Lifetime* on motor and all parts
ISD1000 Series — Lifetime* on motor, all parts and service
CMD9900 Series — Lifetime* on motor, 5 years* on parts
PRO99 Series — Lifetime* on motor and all parts
* for as long as you own your home This warranty is non-transferable
Who Gets the Warranty?
This warranty applies only to the consumer who originally purchased the
product
Geographic Scope:
This warranty applies only to Genie products purchased in the United
States and Canada
What We Will Do:
If your Genie product is defective, we will send replacement parts or, at
our option, a replacement unit at no charge to you, excluding shipping,
handling and labor costs If we send replacement parts for your Genie
product, we may use new or reconditioned parts If we choose to send a
replacement unit, we may use a new or reconditioned one of the same or
similar design
Limitations:
IMPLIED WARRANTIES, INCLUDING THOSE OF FITNESS FOR A
PARTICULAR PURPOSE AND MERCHANTABILITY (AN UNWRITTEN
WARRANTY THAT THE PRODUCT IS FIT FOR ORDINARY USE) ARE
LIMITED TO ONE YEAR FROM DATE OF PURCHASE GENIE WILL NOT PAY
FOR: LOSS OF USE OF YOUR GENIE PRODUCT OR PROPERTY DAMAGE
CAUSED BY YOUR GENIE PRODUCT OR ITS FAILURE TO WORK; ANY
SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES; ANY DAMAGES
RESULTING FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT
Some states and provinces do not allow limitations on how long an
implied warranty lasts or the exclusion of incidental or consequential dam-
ages, so the above exclusions and limitations may not apply
This warranty is the only one we will give on your Genie product, and
it sets forth all our responsibilities regarding your Genie product.
There are no other expressed warranties.
State and Province Rights: This warranty gives you specific legal rights,
and you may also have other rights that vary from state to state and prov-
ince to province
How to Get Warranty Service:
To get warranty service for your Genie product, you must
provide proof of date, and place of purchase of the product
1. Do-It-Yourself Service:
Call Genie Customer Service toll free at 1-800-354-3643, or visit
our website at wwwgeniecompanycom Trained Genie
representatives will assist in diagnosing the problem and will
arrange to supply you with the required parts for do-it-yourself
repairs Trained service representatives are available Monday -
Friday, 8:00 AM - 11:00 PM, and on Saturday, 11:00 AM - 8:00 PM
Eastern Time (subject to holidays)
2. Service From Authorized Dealers:
You can obtain the name of a Genie Factory Authorized Dealer
by calling the Genie Dealer Locator Service at 1-800-654-3643
If an Authorized dealer provides warranty service, Genie will not
reimburse you or otherwise be responsible for any labor charg-
es Your choice of one of the above described service options is
your remedy under this warranty
What This Warranty Does Not Cover:
• Batteries (which are considered replacement parts)
• Installation
• Commercial use
• Defects resulting from accidents
• Damage while in transit to our service location or damage
from alterations
• Misuse or Abuse
• Lack of proper maintenance
• Unauthorized repairs or modifications of the product
• Affixing of any attachment not provided with the product
• Programming of Remote Control Devices
• Programming of Keypads
• Safe-T-Beam® adjustment/cleaning
• Staples through wiring
• Pinched or broken wires
• Carriage disengaged
• Force Control adjustments
• Door out of balance
• Broken springs or cables
• Power outages
• Use of extension cords
• Missing or damaged parts on discounted, clearanced, final
sale or taped cartons
• Phantom operations
• Fire
• Flood
• Acts of God
• Failure to follow the Owner’s Manual
29
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
T
E
A
R

A
L
O
N
G

D
O
T
T
E
D

L
I
N
E

/
A
R
R
A
N
c
A
R

E
N

L
A

L
î
N
E
A

D
E

p
u
N
T
O
S

/

A
R
R
A
c
h
E
R

L
A

L
I
G
N
E

E
N

p
O
I
N
T
I
L
L
E
No c.O.D. shipments. please include check or money
order, made payable to The Genie company. Do not
send cash. Allow 3-4 weeks for delivery. We accept
Visa or Mastercard on phone orders only.
1-800-354-3643. please have part number and credit
card ready.
Please add local sales tax if you reside in one of
the states listed.
California
Connecticut
Florida
Georgia
Illinois
Indiana
Maryland
Massachusetts
New Jersey
New York
Ohio
Tennessee
Virginia
Wisconsin
Michigan
TOTAL ORDER $
SHIPPING & HANDLING $ 5.00
STATE SALES TAX $
GRAND TOTAL $
Garage Door Opener Accessories
Accesorios para abridores de garajes
Accessoires pour ouvre-porte de garage
(GIT-1) Deluxe Remote Control with Intellicode
®
- Allows remote operation of garage door
Controlador remoto de lujo con Intellicode
®
- proporciónar operación remoto de la puerta del garaje
Télécommande de luxe avec Intellicode
®
- permettre opération éloign´´de porte de garage
(GIT-2) 2-Button Remote Control with Intellicode
®
- Allows remote operation of 2 garage doors
Controlador remoto de 2 funciones con Intellicode
®
- proporciónar operación remoto de dos las puertas del garaje
Télécommande à 2 fonctions avec Intellicode
®
- permettre opération éloign´ deux portes de garage
(GIT-3) 3-Button Remote Control with Intellicode
®
- Allows remote operation of 3 garage doors
Controlador remoto de 3 funciones con Intellicode
®
- proporciónar operación remoto de tres las puertas del garaje
Télécommande à 3 fonctions avec Intellicode
®
- permettre opération éloign´ trois portes de garage
(GPWC-2WLB) Lighted Wall Console - Operates Garage Door. Independent light control. Security vacation lock
Consola de pared de 3 funciones - Acciona la puerta del garaje. control de luz independiente. cerradura de seguridad para vacaciones
Console murale à trois fonctions - Actionne la porte de garage. commande d’éclairage indépendante. Interrupteur de verrouillage de sécurité
(GMI-3) 3-Button Mini R emote Control with Intellicode
®
- Fits easily into pocket or purse
Minicontrolador remoto de 3 funciones con Intellicode
®
- cave fácilmente en el bolsillo o cartera
Mini télécommande à 3 fonctions avec Intellicode
®
- se glisse dans la poche de veston ou le sac à main
(GWKP) Wireless Keypad Entry System - Operates Intellicode
®
Garage Door Openers without Remote control or key
Sistema de entrada por teclado numérico inalámbrico - Acciona los abridores de puertas de garaje Intellicode
®
sin control remoto o llave
Système d’ouvre-porte de garage à clavier sans fil - Actionne les ouvre-porte de garage avec Intellicode
®
sans télécommande ni clé
(GLU-3) 1/4 oz. Tubes Screw Drive Lubricant (3) - Ensures proper equipment wear protection
1/4 once Lubricante de tornillo accionar (3) - Asegura componente correcto protección por deterioro
La onza 1/4 Lubricant de la vis (3) - Garantir componant exact par systéme défense vers user
(GWB) Universal Wall Button - provides additional convenient inside operation of door
Botón de pared universal - proporciona operación conveniente de la puerta desde el interior
Bouton mural universel - Actionne l’ouvre-porte de l’intérieur du garage
(GPS-5) Perfect Stop
®
- Ensures perfect parking
Stop Perfecto
®
- Asegura el estacionamiento perfecto
Butoir Perfect Stop
®
- permet de stationner à la perfection dans le garage
(GSXL-8) Excelerator Screw Drive Extension Kit - An eighteen inch Extension to increase the travel of a Screw Drive Opener to accommodate an eight foot door
El extensión deslizante de Excelerator Screw Drive - una extensión de 18 pulgadas para aumentar la carrera de un abridor deslizable de tornillo, para acomodar una puerta de 8 pies (2,43 m.)
Nécessaire de rallonge du Excelerator Screw Drive - Rallonge de 30 dm (18 po) prolongeant la course de l’ouvre-porte Screw Drive pour une porte de 2,4 m (8 pi) de hauteur
(GIRU-1T) Universal Conversion Kit - converts any Garage Door Opener to a secure radio signal system. Kit includes a Remote control, Receiver and Transformer
Juego de conversión universal - convierte cualquier abridor de puerta de garaje a un sistema de señal de radio seguro. El juego incluye un control remoto de abridor de puerta de garaje,
receptor y transformador
Nécessaire de conversion universel - Transforme tout ouvre-porte de garage en système de sécurité à signal radio. comprend une télécommande d’ouvre-porte de garage, un récepteur et
un transformateur
60 WATT Enhanced/Rough Service Light Bulb - Ensures proper equipment compatability
Bombilla de 60 Vatios - Asegura componente correcto de sistema
éclairage de 60 WATT - Garantir componant exact par systéme
(GER-2) Emergency Release Kit - provides access to garage from outside in the event of an electrical power failure
Juego de pica-porte de pestillo - permitir entrtada desde por fuera de garaje porque corte de eléctrico
Nécessaires de Déclenchement de secours - Le nécessaire de déclenchement de secours est conçupour vous permettre d’accéder à votre garage depuis l’extérieur en cas de panne de
courant et lorsqu’il
STB Adapter Brackets (2) - used in conjunction with standard STB Mounting Brackets. They provide additional clearance along with mounting options
El adaptador pone entre paréntesis (2) - usado en unión con paréntesis uniformes de montar de STB, ellos proporcionan el espacio libre adicional junto con mortar las opciones
Crochets d’adaptateur - utilisé conjointement avec STB standard monter les crochets, ils fournissent le dégagement supplémentaire avec monter d’options
pas d’expédition contre remboursement. Veuillez inclure un
chèque ou un mandat bancaire, le payable fait à The Genie
company. N’envoyez pas d’argent comptant. Accordez de
3 à 4 semaines pour la livraison. Nous acceptons les com-
mandes par téléphone avec paiement par carte de crédit Visa
ou Mastercard. 1-800-354-3643. Ayez sous la main le numéro
de la pièce et celui de la carte de crédit.
Veuillez indiquer les taxes de vente locales si vous résidez
dans l’un des états répertoriés ci-dessous.
Californie
Connecticut
Floride
Georgie
Illinois
Indiana
Maryland
Massachusetts
New Jersey
New York
Ohio
Tennessee
Virginie
Wisconsin
Michigan
COMMANDE TOTALE $
MANUTENTION ET EXPéDITION $ 5.00
TAXE DE VENTE $
TOTAL GLOBAL $
No se aceptan pedidos de pago contra entrega (cOD).
Sírvase incluir su cheque o giro postal, la cuenta pagad-
era hecha a The Genie company. No envíe dinero en
efectivo. concédanos 3 a 4 semanas para la entrega.
Aceptamos pedidos telefónicos de Visa o Mastercard.
1-800-354-3643. Sírvase tener listos los números del
modelo y de la tarjeta de crédito.
Sírvase agregar el impuesto de ventas local si usted
reside en uno de los siguientes estados:
California
Connecticut
Florida
Georgia
Illinois
Indiana
Maryland
Massachusetts
New Jersey
New York
Ohio
Tennessee
Virginia
Wisconsin
Michigan
TOTAL DEL PEDIDO $
FLETE Y MANEJO $ 5.00
IMPUESTO DE VENTAS ESTATAL $
GRAN TOTAL $
prices on Reverse Los precios en otro lado Les prix sur l’autre côté
Ordering Instructions Las Instrucciones que Ordenan Instructions Commandant
3 1 2
4 5 6
7 8 9
0
T
E
A
R

A
L
O
N
G

D
O
T
T
E
D

L
I
N
E

/
A
R
R
A
N
c
A
R

E
N

L
A

L
î
N
E
A

D
E

p
u
N
T
O
S

/

A
R
R
A
c
h
E
R

L
A

L
I
G
N
E

E
N

p
O
I
N
T
I
L
L
E
Garage Door Opener Accessories Order Form
Formulario de pedido de accesorios para abridores de puertas de garaje
Formulaire de commande des accessoires pour ouvre-porte de garage
MODEL DESCRIPTION PRODUCT CODE PRICE (US$)* QTY. TOTAL
MODELO DESCRIPCIÓN CÓDIGO PRECIO* CANTIDAD TOTAL
MODÈLE DESCRIPTION CODE DU PRODUIT PRIX ($ US)* QTé TOTAL
Deluxe Remote control with Intellicode
®

GIT-1 controlador remoto de lujo con Intellicode
®
33069R $34.95
Télécommande de luxe avec Intellicode
®
2-Button Remote control with Intellicode
®

GIT-2 controlador remoto de 2 funciones con Intellicode
®
33069S $44.95
Télécommande à 2 fonctions avec Intellicode
®
3-Button Remote control with Intellicode
®

GIT-3 controlador remoto de 3 funciones con Intellicode
®
33069T $49.95
Télécommande à 3 fonctions avec Intellicode
®
Lighted Wall console
GPWC-2WLB consola de pared encender 34292R $13.95
console murale avec éclairage
3-Button Mini Remote control with Intellicode
®


GMI-3
Minicontrolador remoto de 3 funciones
34909R $39.95

con Intellicode
®

Mini télécommande à 3 fonctions avec Intellicode
®
Wireless Keypad Entry System
GWKP Sistema de entrada por teclado numérico inalámbrico 35282R $49.95
Système d’ouvre-porte de garage à clavier sans fil
1/4 oz.Tube Screw Drive Lubricant (x 3)
GLU-3 1/4 once Lubricante de tornillo accionar (x 3) 34965R $1.95
La onza 1/4 Lubrifiant de la vis (x 3)
universal Wall Button (unlit)
GWB Botón de pared universal (unlit) 34960R $4.95
Bouton mural universel (unlit)
perfect Stop
®

GPS-5 Stop perfecto
®
34964R $4.95
Butoir perfect Stop
®
Screw Drive Extension Kit (For Excelerator)

GSXL-8
El extensión de cadena deslizable (para Excelerator)
33523S $34.95

Nécessaire de prolongement
du coulisseau (pour Excelerator)
universal conversion Kit
GIRU-1T Juego de conversión universal 33154R $49.95
Nécessaire de conversion universel
60 Watt Enhanced/Rough Service Light Bulb
LIGHT BULB Bombilla de 60 Vatios 26210A.S $2.95
éclairage de 60 Watt
Emergency Release Kit
GER-2 Juego de pica-porte de pestillo 34963R $29.95
Nécessaires de d’clenchement de secours
STB Adapter Brackets (2)

ADAPTER
El adaptador pone entre paréntesis (2) 34439R.S $4.95

BRACKET
crochets d’adaptateur (2)
MAIL ORDER FORM TO:
ENVIAR HACER UN PEDIDO DE MERCANCIA A:
METTRE à LA POSTE LE ARRANGEMENT à:
The Genie Company
22790 Lake park Blvd.
Alliance, Ohio 44601-3498
NAME / NOMBRE / NOM
ADDRESS / DIREccIóN / ADRESSE
cITY / cIuDAD / VILLE STATE / ESTADO / éTAT ZIp / cóDIGO pOSTAL / cODE pOSTAL
SHIP ORDER TO:
ENVIAR MERCANCIA CON:
EXPéDIER MARCHANDISE POUR:
* prices subject to change without notice
* Valoran el cambio con sujeción a sin nota
* Les prix assujettissent pour changer sans la notification
®

GIT-1
GIT-2
GIT-3
GPWC-2WLB
GER-2
LIGHT BULB
GIRU-1T
GSXL-8
GPS-5
GWB
GLU-3
GWKP
GMI-3
STB BRACKET
EXTENSIONS
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
30

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close