Manual
Pile Design [NEN method]

Scia Engineer

The information contained in this document is subject to modification without prior notice. No part of this document may be reproduced, transmitted or stored in a data retrieval system, in part or in total, in any form or by any means, electronic or mechanical, for any purpose without the express permission in written from the publisher. SCIA Software is not liable for any direct or indirect damages resulting from imperfections in the documentation and/or the software. © Copyright 2009 Nemetschek Scia. All right reserved.

1

Scia Engineer

Introduction ............................................................................................................................................. 3  Geotechnics service ............................................................................................................................... 4  Soil Profile CPT ....................................................................................................................... 4  Geotechnics setup .................................................................................................................. 8  Pile Plan ................................................................................................................................. 10  Check – Pile plan design ...................................................................................................... 16  Check – Pile plan verification .............................................................................................. 18  Output tables ......................................................................................................................................... 21  Limitations ............................................................................................................................................. 25 

2

Scia Engineer

Introduction
Pile design functionality is the new tool in SCIA Engineer. It enables the user to perform the design/verification of bearing piles in accordance with NEN 6740 and NEN 6743. This functionality is available for NEN and EC-EN standards. The Piles are defined as a new type of support and the piles are integrated with the model and the soil profiles. The soil profiles are generated from the Cone Penetration Test data (.Gef – Geotechnical exchange format file [ASCII}). A link has been provided to import the CPT data from the net. This facilitates the user to select the CPT data (gef file) available in the specified location. An automatic interpretation tool [NEN rule] has been used for generating the soil profile. The predefined soils are used by this interpretation tool. The piles are defined as a new type of support and are completely linked with the Model. Predefined shapes are used to define the piles. All the relevant parameters required by the pile are defined as per guidelines given by Dutch standards. The soil profiles from CPT are linked with the pile plan and are used for design/verification. The piles are represented in the 3D model and their display is controlled by view parameter settings. The pile design option will facilitate the user to evaluate the pile tip level and the bearing capacity at tip level. The verification option will result in load- settlement curves from ULS and SLS and calculate the pile settlement. The program also enables the user to generate Non-linear functions from load-settlement curves and the generated functions can be associated to the supports.

3

Scia Engineer

Geotechnics service
A New service “Geotechnics” has been introduced in SEN. This service is common for Pile design and Pad Foundation. This service is available only if the Pile design/Pad foundation functionality is selected.

Soil Profile CPT
The soil profile CPT is a new library in SEN, It enables the user to generate the soil profiles from CPT data. The generated soil profiles are used in Pile plan design /verification. The UI dialog will be as shown below:

The user has to select the GEF file using the easy button. The program also allows the user to get the gef file from the link “Import from Dino”. The program generates the soil profile from the CPT data. In this dialog, two soil profiles are drawn. The left profile is the result of the interpretation from the CPT data with the CPT data drawn to the left of it and the other profile is the edited geometry. The interpretation is based on the NEN model (Stress Dependent) based on NEN 6740. The default min layer thickness is 0.5m. The program allows the user to edit the interpreted soil profile. The interpreted soil profile consists of only the soils which are defined by the NEN model. The user can edit the interpreted geometry of the soil profile with the user defined soils. The soils used by NEN are made available in the database of soil library and the user will be able to define the new soils. The interpreted geometry can be retrieved at any time by using the option “Copy interpreted geometry to edited geometry. .

4

Scia Engineer

The soil profile will be used as an input for the pile plan design/verification. After generating the soil profile, a library object (CPT) has been added into the Soil profile CPT library. The CPT object is represented graphically in the 3D model as a borehole object in SEN. The user has to use the “Draw CPT in Model window” option to draw the CPT in the model.

The position of CPT is from the input data. The XY coordinates are defined by the user and the top level is the test level. The test level has been read from the CPT data.

The user has to specify the additional data of the soil profile which are required during the design/verification.

The default values are specified in the properties. The values for Top of positive skin friction zone and bottom of negative skin friction zone will be entered by the user. Phreatic level The level between the dry soil and the wet soil OCR The value of Overconsolidation ratio of bearing layer determines whether the maximum pile tip resistance to be reduced due to Overconsolidation or not. Overconsolidation is normally caused by loads which were applied to the bearing layer over a long period of time. The range and effect of OCR on Pile tip resistance are OCR<=2 – No effect on Pile tip resistance 2< OCR < 4 – Maximum Pile tip resistance is reduced by 33% OCR > 4 – Maximum Pile tip resistance is reduced by 50% Top of PSFZ Top of Positive skin friction zone – The bottom of the zone coincides with the pile tip level. For a prefabricated pile with widened tip, the top of the zone may never be placed above the widening. Bottom of NSFZ Bottom of Negative skin friction zone – The top of the zone coincides with the surface or excavation level. There is a strong relationship between skin friction and the soil layers, the skin friction zones are constructed from complete layers. Expected GL settle Expected ground level settlement - The expected ground level settlement determines how the negative skin friction has to be incorporated in the calculations.

5

Scia Engineer

If the expected settlement is 0.02m, negative skin friction is negligible and will not be considered. For the values ranging from 0.02m to 0.10m, the effect of negative skin friction is directly incorporated into the calculated pile settlement by adding half of the expected ground level settlement to the total pile settlement. For values >0.10m, the maximum forces due to negative skin friction are calculated. These forces are then used to determine the negative skin friction on the pile settlement.

CPT Data
The gef file contains the relevant CPT data. The data include the Level, qc, friction, water pressure and friction number. The availability of the above properties are depends on the gef file. The program identifies the input data and will generate the soil profile based on the input data and the NEN model (interpretation rule). Import from Dino: This option allows the user to import the gef files from the map. The available CPT’s in the region will be shown to the user and the user will select the CPT. The program will generate the soil profile for the selected CPT.

6

Scia Engineer

NEN Model (Stress dependent)
The NEN rule is considered to be a more common and is used for interpretation of the soil profile. This model uses 14 different rules and is based on the Dutch standard NEN 6740. Each rule describes certain soil types by defining the relationship between CPT resistance and friction ratio. The friction ratio is defined as the shear resistance as a percentage of the cone resistance. The soils used by the NEN model and its properties are defined in soil library. The soil types used by NEN model are, Gravel, slightly silty, moderate Sand, clean, stiff Sand, slightly silty, moderate Sand, very silty, loose Loam, very sandy, stiff Loam, slightly sandy, weak Clay, very sandy, stiff Clay, slightly sandy, moderate Clay, clean, stiff Clay, clean, weak Clay, organ, moderate Clay, organ, weak Peat, moderately preloaded, moderate Peat, not preloaded, weak.

Soil library
Soil library is a new standard library in SEN. The soil materials and its properties are specified in this library. The database of soils used by the NEN model is created in db4 file and will be loaded automatically. The program also enables the user to define the new soils. The user defined soils will be used to edit the interpreted geometry of the soil profile.

Description Description of the Soil Soil type The soils can be any of the following types: Gravel, Sand, Loam, Clay, Peat

7

Scia Engineer

Gamma unsaturated Dry unit weight of the soil Gamma saturated Saturated unit weight of the soil Friction angle Angle of internal friction for the soil – The value must be between 0 - 90 degrees Median This property applies to soil types sand and gravel. The size of median will influence the value of S which is used to determine the positive skin friction. For sand with median >0.6mm, the values of S will be reduced by 25% and for gravel with median >2mm S will be reduced by 50%. Min/Max void ratio The min/max void ratios are used to allow for compaction of soils. The values must be between 0 and 1. The default values of 0.4 and 0.8 are recommended for Dutch conditions.

Geotechnics setup
A New setup for “Geotechnics” has been introduced in SEN. This setup is common for Pile design and Pad Foundation. The parameters for Pad foundation are detailed in another chapter.

The parameters described in the setup are required for the Pile plan design/verification.

8

Scia Engineer

Superstructure type The type of structure “House” and “Other” can be selected from the drop down list. Based on the type of structure, the requirements for both the limit states and the number of CPTs are carried out. Rigidity of Superstructure The superstructure can be specified either Rigid or non-rigid. This parameter influences the calculation. The sigh factor depends on the rigidity of the structure. Use all CPTs for all pile plans If this option is selected all the soil profiles will be automatically associated to all the Pile plans. If the user wishes to manually associate the CPTs to pile plans this option must be unchecked. Max allowed settlement The user can specify the maximum allowed settlements for the limit states. Overrule parameters The parameters listed under this can be overruled, If not the parameters would be determined according to the standard or calculated. The user has to make sure that the overruling of parameters is allowable. Factor sigh This factor depends on the number of CPTs and the number of piles under rigid super structure. The factor is derived from table 1 of NEN 6743 SF for materials Safety factor for materials – Derived from table 3 in NEN 6740 SF for NSF Safety factor for negative skin friction – Derived from NEN 6740 11.5.1 Area The influence area per pile, to be used in the calculation of negative skin friction for pile groups. If this option is not overruled, the program calculates the influence area. This is done by calculating the average pile distance with in the pile group (D avg). Area = D avg*D avg. Use Pile group The calculation of negative skin friction depends on whether piles are to be considered as single or group. When Piles are within 5m, the piles form a pile group, if not they are considered as single piles. Overrule excavation If this option is checked, the excavation level will not be taken into account. Trajectory The trajectory is specified by start and end limit above/below the reference level. The interval of trajectory determines the number of calculations to be performed. The top and bottom limits of the trajectory must meet the following requirements. The start trajectory must be at least 5*dmin below the lowest surface level, excavation level and pile head level. (dmin- smallest cross section dimension of the pile) The end trajectory must be at least 4*Deq above the deepest level of the shallow CPT. Deq – Equivalent diameter. The interval has to be chosen in such a way that the maximum number calculations should not exceed 151.

9

Scia Engineer

Pile Plan
Pile plan library is a new standard library in SEN. The piles are defined in the library and are associated to the supports.

Soil profile CPT The soil profile generated from the CPT data must be associated with the Pile plan. At least one soil profile is to be associated with every pile plan. The design/verification of piles could be performed based on the soil profile. In the Geotechnics setup page, if the option “Use all the CPTs for all Pile plans” is checked, all the soil profiles will be directly associated with all the pile plans. If the user wishes to associate the soil profiles manually, this option must be unchecked. The standard selection tool with the list of available CPTs is displayed in the left and the associated CPTs are displayed in the right window. There is also link to the soil profile CPT library in the selection dialog.

10

Scia Engineer

Pile Definition The properties of the pile and the relevant parameters are defined in a special dialog. This dialog is opened through the easy button . This dialog is language independent. All the parameters are only in English

Shape of Pile The user can specify the shape of pile by selecting the any of the shape which is represented graphically on the left part of the dialog. The selected shape will be displayed in the Pile shape dialog. Dimensions Based on the shape of pile, the user has to specify the dimensions for the Pile. The dimensions are to be specified in “m”. Rect Pile Base width and base length of the Pile Rect Pile with enl base Width, length and height of base & width and length of shaft Steel Section Base width and base length of the Pile Round pile Diameter of Pile Round tapered pile Diameter at tip and increase in diameter Round hollow pile Internal and external diameter of pile Round enlarged base Diameter and height of base and Pile diameter Round lost tip Diameter and height of base and Pile diameter Round driven base Diameter and height of base and Pile diameter Pile type The program will display the predefined pile types that can be selected for the chosen pile shape in the dropdown list. The user has to select the type of pile from the list. If the predefined type is selected, the corresponding pile data are filled automatically and these data cannot be edited. Selection of User defined type will allow the user to enter all the data manually. s Pile factor for the shaft friction. For cohesive soils, the value for this factor is according to NEN 6743-1:2006 and depends on the soil material. For non-cohesive soils (sand, gravel) the value for s depends on the pile type. Hence it can be specified by selecting one of the predefined pile

11

Scia Engineer

types from the dropdown box. As a result the actual value for as will be displayed in the current value box. If User defined is selected as the subtype, only the parameter value is entered and the relation of the subtype with the pile type no longer applies. It has the following consequences: The value entered for s, valid for sand and gravel layers, will NOT be adjusted for any instance of coarse grain (NEN 6743-1:2006 Table 3) The exception for the determination of the pile tip shape factor ß cannot be met because it is impossible to determine that a cast-in place pile with a regained steel driving tube is applied (NEN 6743-1:2006 5.4.2.2.3). The check on dL (length of positive skin friction zone) when a weighted tip is applied cannot be performed because it cannot be determined that a pre-fabricated pile is used (NEN 6743-1:2006 5.4.2). For cohesive soils (clay, peat, loam) the factor according to the standard is depth-dependent and thus has no single value. As a result the current value box displays N.A. (Not Applicable) as the value can not be shown. If User defined is selected as the subtype, only the parameter value is entered. That value can and will be displayed as current value.  p p is the pile factor for the pile point. As s for sand/gravel, p depends on the pile type for its value. Therefore it can be specified by selecting one of the standard pile types from the combo box. As a result the actual value for p will be displayed in the current value box. Select User defined to specify any other value for p. If User defined is selected for p, the pile factor for the pile point, then the exception for ‘continuous flight auger’ piles cannot be taken into account for the reduction of qc-values when determining qc;III;mean. The reason for this is that it cannot be determined if a continuous flight auger pile is used (NEN 6743-1:2006 5.4.2.2.1). LS Curve Load-Settlement curves NEN 6743-1:2006 Figures 6 and 7 contain only lines for three subtypes - Displacement pile - Continuous flight auger pile - Bored pile Material The material of the user defined pile is selected. Young’s modulus The corresponding elasticity modulus is provided automatically for concrete, steel and timber and cannot be edited. If the material "User defined" is selected then the Young’s modulus must also be specified. Slip layer The slip layer for the pile has been specified Rep. Adhesion The corresponding representative adhesion is provided automatically and cannot be edited, unless the value User defined is selected, in which case the required Representative adhesion should be input. Pile tip Level When we define /create the pile plan, the level type will be user defined and the user has to specify the pile tip level. After the pile design has been performed the level type automatically set to calculated level and the calculated pile tip level will be set for the pile tip level.

Type Z The stiffness type for the supports in the Z direction has to be specified. For Linear analysis, the user has to choose either rigid/flexible type.

12

Scia Engineer

For Non-linear analysis in addition to Rigid/Flexible, the non-linear option will also be available. If this option is selected, the Non-linear function library will be associated with the support. LS curves The Load settlement curves are the result of Pile verification. After Pile verification, the easy buttons will enable the user to view the LS curves. The ULS and SLS curves will be displayed independently.

NLF If support non-linearity functionality is selected, a new action button will be enabled in the Pile plan library after the pile verification.

13

Scia Engineer

This action button will generate the two non-linear functions each from ULS Load settlement curve and SLS Load settlement curve. The stiffness value is also proposed for the function selected. By default the function from ULS will be set as default.

New nodal support
A new nodal support type “Pile” has been added into the standard support. The pile plan library is associated to the “Pile” support. The standard properties of the support are defined. The type Rz is directly read from the pile plan library and will be used by all the supports during the analysis. The supports are grouped by the pile plan. By default, the value of X & Y will be set to “Free” and the user may change only these two values. The support can have any condition. By default the support is a hinge i.e. Rx, Ry and Rz are fixed, Mx, My and Mz are free. In case Rz is negative i.e. the pile is in tension, no check is executed for the pile plan and a warning is displayed.

The properties of the support are,

The supports are represented in the Model as shown below

14

Scia Engineer

The colour of the Pile is from the Pile plan library. The colour of piles are controlled by the view flag parameters under the tab “Model”

The option “colour by pile plan” is by default checked and if the user wishes to see all the piles are to be represented by colour of supports, the user has to uncheck this option. The display of pile labels for the supports is also controlled by the view parameters.

15

Scia Engineer

Check – Pile plan design
This option enables the user to calculate the pile tip level. The design/ verification of bearing piles are performed based on the guidelines given by NEN 6740 and NEN 6743. This option is limited to NEN and EC-EN standards. The design is performed only for bearing piles which are subjected to static or quasi static loads that cause compressive forces in the piles. The calculation of pile forces and pile displacements are based on cone penetration test. Any possibility of tension in piles and horizontal displacements of piles and/or pile plans are not taken into account. In Pile Design (preliminary design), a single pile is always assumed and the calculations performed are based on a single pile for ULS. Any possible pile plan is disregarded when using the Pile design option. Hence a non-rigid superstructure is assumed and pile group effects are not considered. – These limitations are explicitly mentioned in the results/ document. The program evaluates the pile tip level where the net bearing capacity of the pile is equal to or more than the maximum load on the pile. After performing the analysis, the pile plan design command will be enabled in the “Geotechnics” service.

The following are the Prerequisites for performing the Pile plan design:  Model of the analysed structure must be properly defined  The reactions of the supports must be known. The procedure used for performing the design is analogous to the procedure for evaluation of results. In the tree menu of service Geotechnics, select the command Pile plan design. Once the command is selected, the appropriate parameters are listed in the Property window.

Selection The user may perform the design either on all pile plans or only selected pile plans. The selection of pile plans is carried in a unique manner. The user may select any one pile and all the piles belong to the selected pile plan will be internally selected and the design will be performed together for all the piles of the pile plan. Load type Pile plan design will be performed only for the result classes. Class Pile plan design will be performed only for the result classes which have the ultimate combinations defined. The filtering will be done automatically by the program and only the result classes which have the ULS combinations will be made available. If no result class is defined by

16

Scia Engineer

the user and only the combinations are defined, the program automatically creates a result class with ULS combination. The design will be performed for the selected pile plans. The calculation will be done after the user presses the Refresh button. The results will be displayed in the preview window.

Calculation process First, for every CPT, the maximum bearing capacity for a single pile is determined as the sum of the maximum bearing capacity of the pile tip and the maximum shaft friction force. The following factor applies to the maximum shaft friction force. The execution factor is not a fixed value here and is dependent on the soil type of the layer, as well as on the depth of the relevant layer. For each layer, the program calculates the generated pile shaft friction in that layer after defining the correct value of s for the relevant layer. Aggregation of the pile shaft friction calculated per layer in this way for the layers affected by pile shaft friction produces the eventual value of the maximum pile shaft friction. Determining the circumference of the pile segment for which the maximum shaft friction force is calculated as follows. If it involves a non-constant circumference, as is the case with tapered wooden piles and piles with a reinforced tip, for example, the standard (NEN 6743, art. 5.4) does not actually provide a solution. In that case, the program calculates the mean circumference of the relevant pile segment. Secondly, the maximum bearing capacity of the foundation is determined. Here, the number of piles, the number of CPTs and whether the structure may be considered as rigid or not (NEN 6743, art. 5.2.2) play a role. In case of a rigid structure, regardless of the number of CPTs, the program calculates the maximum bearing capacity of the foundation based on the average bearing capacity of a single pile, multiplied by the total number of piles, since the foundation element contains all of the piles. In case of a non-rigid structure, determination of the maximum bearing capacity of the foundation depends on the number of CPTs. If there are more than three CPTs, the definition is again based on the average bearing capacity of a single pile, whereas if there are three CPTs or less, the minimum bearing capacity of a single pile is used. In this case, the bearing capacity of a single pile is not multiplied by the total number of piles because the foundation element consists of a single pile. Pile plan design The required pile tip level is calculated in a user-defined pile tip trajectory. This trajectory is defined by means of start and end limit (Defined in the Geotechnics setup page). The interval of trajectory determines the number of calculations to be performed. When defining the trajectory the user need not to specify the levels of positive and negative skin friction. If needed, these levels are automatically adjusted for each calculation step. The value Rz is only considered for the design. The horizontal forces/ any possible rotations are not considered for the design. The maximum load (from Rz) on the support is determined from all the piles of selected pile plan. This load will be used for calculation of the pile tip level. This value is used as a stopping criterion for the calculation. As the level is detected by the program where the calculated net bearing capacity equals or more than the maximum load the calculation is stopped and the program will display the calculated capacity at the this level. If within the trajectory no level is found with the net bearing capacity is not met the maximum load, the program returns the pile tip level as “zero” and a warning “The required bearing capacity is not met with in the trajectory, Hence the level can not be calculated”

17

Scia Engineer

If all the piles in the pile plan are subjected to tension, the program will not perform the design and hence the pile tip level will not be calculated and a warning will be issued “All the piles in the pile group are subjected to tension. The design could not be performed for tension piles”. The user defined level will be used by the program. If one or more piles in the pile plan are subjected to tension, the maximum load will be determined from the other piles which are not subjected to tension. The design has been performed for this maximum load and a warning is issued “There are one or more piles in the pile plan is subjected to tension” The pile tip level calculated by the program is updated in the pile plan library and the supports of all the piles in the pile plan will be updated with this calculated level.

The drawing of piles in the 3D model will also get updated. The results can be viewed in the preview window and in the document. Any changes made in the Geotechnics setup /soil profile / soil will not affect the analysis results but affects the pile design results. In such case, the user has to perform the pile plan design in order to get the new results. If there is any change in the model/load (i.e.) if the analysis results become invalid, the pile plan design results are also not valid. In such case, the pile tip is automatically set as user defined level. The user has to perform the analysis and the design in order to get the new results.

Check – Pile plan verification
The verification of bearing piles is performed based on the guidelines given by NEN 6740 and NEN 6743. This option is limited to NEN and EC-EN standards. The verification is performed only for bearing piles which are subjected to static or quasi static loads that cause compressive forces in the piles. The calculation of pile forces and pile displacements are based on cone penetration test. Any possibility of tension in piles and horizontal displacements of piles and/or pile plans are not taken into account. The entire pile plan is considered during verification and the group effects are considered. The program results the Load-settlement curve from ULS and SLS. This option carries out all required calculations such as bearing capacity, settlement and negative skin friction. After performing the analysis, the pile plan verification command will be enabled in the “Geotechnics” service.

The following are the Prerequisites for performing the Pile plan design:  Model of the analysed structure must be properly defined  The reactions of the supports must be known. The procedure used for performing the verification is analogous to the procedure for evaluation of results. In the tree menu of service Geotechnics, select the command Pile plan verification. Once the command is selected, the appropriate parameters are listed in the Property window.

18

Scia Engineer

Selection The user may perform the verification either on all pile plans or only selected pile plans. The selection of pile plans is carried in a unique manner. The user may select any one pile and all the piles belong to the selected pile plan will be internally selected and the verification will be performed together for all the piles of the pile plan. Load type Pile plan verification will be performed only for the result classes. Class Pile plan verification will be performed only for the result classes which have the ULS and SLS combinations defined. The filtering will be done automatically by the program and only the result classes which have the ULS & SLS combinations will be made available. If no result class is defined by the user and only the combinations are defined, the program automatically creates a result class with ULS + SLS combination. The verification will be performed for the selected pile plans. The calculation will be done after the user presses the Refresh button. The results will be displayed in the preview window.

To perform the verification, the design loads (ULS & SLS) on all the piles of the pile plan are considered. The result of this calculation is the Load settlement curve and the settlement at tip. Skin Friction zones The essential requirements to calculate the positive and negative shaft friction resistance are specified in NEN 6743. For the positive skin friction zone, the bottom of that zone coincides with the pile tip level, and for a prefabricated pile with a widened base, the top of that zone may never be above the widening (NEN 6743 art. 5.4). For the negative skin friction zone, the top of this zone coincides with the ground level or excavation level. Given the strong link between skin friction and the soil layer classification, the skin friction zones are constructed of entire layers. This means that both the top of the positive skin friction zone and the bottom of the negative skin friction zone should always coincide with a layer boundary in the corresponding soil profile. In order to satisfy these requirements in the bearing piles model, the skin friction zones are defined as mentioned below. The bottom of the positive skin friction zone automatically coincides with the pile tip level and therefore does not have to be entered. The top of the positive skin friction zone is specified by the user as a level relative to the reference level.

19

Scia Engineer

The top of the negative skin friction zone automatically coincides with the ground level or excavation level and therefore does not have to be entered. The bottom of the negative skin friction zone is specified by the user as a level relative to the reference level. Pile verification results: The results can be viewed in the preview window and the document. The load –settlement curves are updated in the pile plan library.

Load- settlement curves: If the problem fully meets all the verification requirements, both the load –settlement curves will be generated. If not the curves may not be generated and warning is issued.

20

Scia Engineer

Output tables
All the output tables of Pile design are made available in the standard document service of SEN. The output tables include the libraries (soil, Soil profile, Pile plan) and the design/verification results.

Soil profile-CPT Input data
1. Soil Profile-CPT
Name Profile Type Interpretation tool Minimum layer thickness [m] Phreatic level [m] Overconsolidation ratio of bearing layer Top of positive skin friction zone [m] Bottom of negative skin friction zone [m] Expected ground level settlement [m] CPT1 CPT Import Interpretation tool 2 0 1 -1 -0.85 0.11

Profile Data
1. Soil ProfileCPT
Top level [m] -0.85 -3.475 -5.495 -7.515 -11.552 -13.57 -17.604 -19.619 -21.633 -23.646 -25.657 -27.666 -29.672 Cl,or,we Pe,npl,w Pe,mpl,m Cl,or,m Cl,cl,st Sa,vsi,l Lo,vsa,s Lo,ssa,w Cl,vsa,s Cl,or,m Cl,cl,we Cl,cl,st Cl,cl,we Clay, organ, weak Peat, not preloaded, weak Peat, mod preloaded, moderate Clay, organ, moderate Clay, clean, stiff Sand, very silty, loose Loam, very sandy, stiff Loam,slightly sandy weak Clay, very sandy, stiff Clay, organ, moderate Clay, clean, weak Clay, clean, stiff Clay, clean, weak Soil name Description

21

Scia Engineer

Profile Diagram

Soil The soils used in the soil profile are filtered and displayed along with the properties.
2. Soil
Name Description Soil Type Gamma Unsaturated [kN/m3] 19 19 19 20 20 20 20 17 20 20 16 15 12 13 Gamma Saturated [kN/m3] 21 21 21 22 20 20 20 17 20 20 16 15 12 13 Friction angle [deg] 37.5 32.5 30 40 30 35 25 17.5 22.5 32.5 15 15 15 15 0.3 0.35 0.35 0.35 0.26 0.26 0.35 0.45 0.25 0.25 0.4 0.45 0.12 0.12 Poisson coeff

Gr,ssi,m Sa,ssi,m Sa,vsi,l Sa,cl,st Lo,ssa,w Lo,vsa,s Cl,cl,st Cl,cl,we Cl,ssa,m Cl,vsa,s Cl,or,m Cl,or,we Pe,npl,w Pe,mpl,m

Gravel, slightly silty, moderate Sand, slightly silty, moderate Sand, very silty, loose Sand, clean, stiff Loam,slightly sandy weak Loam, very sandy, stiff Clay, clean, stiff Clay, clean, weak Clay, slightly sandy, moderate Clay, very sandy, stiff Clay, organ, moderate Clay, organ, weak Peat, not preloaded, weak Peat, mod preloaded, moderate

Gravel Sand Sand Sand Loam Loam Clay Clay Clay Clay Clay Clay Peat Peat

22

Scia Engineer

Pile plan Pile data
1. Pile Plan
Name SoilProfile_CPT Pile definition Pile Type Material Level type Piletip level [m] PPlan1 PPlan2 CPT1, CPT1, Rect 500 X 500 Round 500 PrefabConcrete DrivenCastPlaceDriving Concrete Concrete Calculated Level User defined -13.000 -5.000

Load settlement curves

Pile plan design Linear calculation, Extreme : Node
Name PPlan1 PictureULS PictureSLS

Selection : All Class : All ULS Note1: The design/verification is performed only for bearing piles which are subjected to static or quasi static loads that cause compressive forces in the piles. The calculation of pile forces and pile displacements are based on cone penetration test. Any possibility of tension in piles and horizontal displacements of piles and/or pile plans are not taken into account. Note2: In Pile Design (preliminary design), a single pile is always assumed and the calculations performed are based on a single pile for ULS. Any possible pile plan is disregarded when using the Pile design option. Hence a non-rigid superstructure is assumed and pile group effects are not considered.

Pile Design check
Pile plan id Case Pile definition Advised pile tip level m] Net bearing capacity Rz at advised level[kN] [kN]

PPlan1

CO1/1

Rect 500 X 500

-13.000

696.61

662.89

23

Scia Engineer

Pile plan verification Linear calculation Selection : All Class : All ULS+SLS Note1: The design/verification is performed only for bearing piles which are subjected to static or quasi static loads that cause compressive forces in the piles. The calculation of pile forces and pile displacements are based on cone penetration test. Any possibility of tension in piles and horizontal displacements of piles and/or pile plans are not taken into account. ULS
Pile plan id PPlan1 Case CO1/2 CPT CPT1 Total Pile plan load [kN] name 662.89 Rect 500 X 500 Advised pile tip Settlement at level[m] tip-Wtip [mm] -5.000 47.9

SLS
Pile plan id Case CPT Total Pile plan load [kN] name Advised pile tip Settlement at level[m] tip-Wtip [mm]

PPlan1

CO1/2

CPT1

513.41

Rect 500 X 500

-5.000

9.6

24

Scia Engineer

Limitations
In pile design (NEN method) functionality many limitations are applied. This functionality is based on the guidelines given by Dutch standards NEN 6740 and NEN 6743. Functionality This functionality is made available only for the EC-EN and NEN standards. Soil profile The soil profiles could be generated only using a valid CPT data and the CPT data should only be in gef (Geotechnical exchange format) file. No other format is supported. The user interface for the generation of soil profile does support only “English language”. Other languages are not supported in this special dialog. The position of CPT (soil profiles) can be defined only in the local coordinates of the project. The global coordinates can not be used. Interpret. Tool The interpretation tool used for generating the soil profile is “NEN rule”. Any tool other than NEN can not be defined or used. The soil types defined by the NEN method alone are used by the interpretation tool and the user defined soils are not used. The user can edit the interpreted soil profile with the user defined soils. Pile plan The special dialog for definition of Pile plan does support only “English Language”. All the parameters required by this dialog are based on NEN. Design/verification The design/verification is performed only for bearing piles which are subjected to static or quasi static loads that cause compressive forces in the piles. The calculation of pile forces and pile displacements are based on cone penetration test. Any possibility of tension in piles and horizontal displacements of piles and/or pile plans are not taken into account.

25

Sponsor Documents

Or use your account on DocShare.tips

Hide

Forgot your password?

Or register your new account on DocShare.tips

Hide

Lost your password? Please enter your email address. You will receive a link to create a new password.

Back to log-in

Close